
migra MPB CAN
Large Format Graphics Compatible LED Display with CANopen Interface
Page 34
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
3.9
Multiple ESC-Sequences
It is possible to combine several partition frames in one complete frame.
This applies to the standard controlling and to the macro list.
The partition frames can be a ESC-sequence or a online text each.
If a online text shall follow after the ESC-sequence, it must be separated
with the “separator sign“ 31
D
= 1F
H
from the ESC-sequence. The
separator itself is not evaluated.
The maximum length of the data unit of a complete frame is 230
characters.
Example:
Data unit = 1B
H
„Z01“ 1B
H
„C002003“ 1B
H
„A301“ 1F
H
„online text“
=> An “online text” with character set 1, on cursor position x=2, y=3 with
foreground colour „yellow“ and background colour „black“ is displayed
(blinking).