3.7.2.8 Querying Bargraphs
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
ESC
Function
Display / Clear
Bargraph-No.
100s
Bargraph-No.
10s
Bargraph-No.
1s
1B
h
„W“
„+“: display
„-“: clear
„0“-„9“
„0“-„9“
„0“-„9“
Displaying a bargraph means to show the last sent value (which is equal
to the reference value after RESET). If a variable is connected to the
bargraph then it will be displayed, too.
Clearing a bargraph means to fill the bargraph area with the current
online background colour (from the last „ESC-A“ frame). „Black“ is used
if the online background colour has been set to „transparent“! If a
variable is connected to the bargraph then it will be cleared, too.
At the moment no more than 255 bargraphs (numbers 0 to 254) are
allowed.
Each connected variable may have a maximum number of 127
characters.
3.7.2.9 Setting Bargraphs
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
ESC
Function
Set
Bargraph-No.
100s
Bargraph-No.
10s
Bargraph-No.
1s
Kind of Data
1B
h
„W“
„=“: Set
„0“-„9“
„0“-„9“
„0“-„9“
„A“: ASCII-
-coded Decimal
Value
Byte 8
Byte 9
Byte 10
Byte 11
Byte 12
Byte 13
Sign
Decimal
Value 10000s
Decimal
Value 1000s
Decimal
Value 100s
Decimal
Value 10s
Decimal
Value 1s
„+“, „-“
„0“-„9“
„0“-„9“
„0“-„9“
„0“-„9“
„0“-„9“