migra MPB CAN
Large Format Graphics Compatible LED Display with CANopen Interface
Page 16
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
3.7.1.1 Selecting a Character Set
Byte 1
Byte 2
Byte 3
Byte 4
ESC
Function
Character set no.
tens
Character set no.
ones
1B
h
“Z” (5A
h
): normal character width
“z” (7A
h
): uniform character width
“0” - “9”
(30
h
-39
h
)
“0” - “9” “
(30
h
-39
h
)
Three character sets are included with the display unit upon delivery:
50 mm (1.97’’) character set (character set “Z00”, “z00”)
75 mm (2.95’’) character set (character set “Z01”, “z01”)
100 mm (3.94’’) character set (character set “Z02”, “z02”).
Existing character sets are overwritten with the new character sets if a
new configuration is downloaded to the display unit!
3.7.1.2 Positioning the Cursor
Byte 1 Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
ESC Function X Position
hundreds
X Position
tens
X Position
ones
Y Position
hundreds
Y Position
tens
Y Position
ones
1B
h
“C”
(43
h
)
“0” - “9”
(30
h
-39
h
)
“0” - “9”
(30
h
-39
h
)
“0” - “9”
(30
h
-39
h
)
“0” - “9”
(30
h
-39
h
)
“0” - “9”
(30
h
-39
h
)
“0” - “9”
(30
h
-39
h
)
3.7.1.3 Configuring Attributes
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
ESC
Function
Foreground colour
Background colour
Blinking
1B
h
“A”
(41
h
)
“0” (30
h
): black
“1” (31
h
): green
“2” (32
h
): red
“3” (33
h
): yellow
“0” (30
h
): black
“1” (31
h
): green
“2” (32
h
): red
“3” (33
h
): yellow
“T” (54
h
): transparent
“0” (30
h
): static
“1” (30
h
): blinking