migra MPB CAN
Large Format Graphics Compatible LED Display with CANopen Interface
Page 31
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
Example:
Macro No.
Macro Command
1
000
ESC-M005E0=1
2
001
ESC-M007E1#1
3
002
ESC-M009E2=1
4
003
ESC-w010
5
004
ESC-M000
6
005
ESC-T+000
7
006
ESC-M000
8
007
ESC-T+001
9
008
ESC-M000
10
009
ESC-F0
11
010
ESC-M000
* Inputs 0 through 2 are queried approximately once per second.
* Text “000” is displayed if input 0 is set.
* Text “001” is displayed if input 1 is set.
This is also the case if the input was set only briefly (at least 100 ms),
for example during the waiting period.
* The display is cleared if input 2 is set.