ZL70550 Application Development Kit (ADK) User’s Guide
Revisio n 1
24
3.3.3 Register Description Window
The
Register Description
window is displayed when a user double-clicks on a register name
(near the address) in the register tabs.
Register
Description
window for the DP_CTRL0 register.
Figure 12 – Sample Register Description Window (DP_CTRL0 register)
The
Register Description
window is an informational dialog and therefore all fields are read-
only. The fields are:
•
Address
: The address of the register is displayed in decimal and in hexadecimal.
•
Name
: This field gives the name of the register. This name is consistent with the
name in the
ZL70550 Programmer User's Guide
.
•
Type
: This field indicates which type of access is permissible. The options are:
−
R: Read only. A write operation is ignored.
−
W: Write only. A read value is meaningless.
−
R/W: Read or write.
•
Bits
: This field indicates how many bits in the register are relevant. The relevant bits
are right justified.
•
Category
: This field indicates the register grouping as defined in the memory map in
the
ZL70550 Programmer User’s Guide
.
•
Reset
: This field indicates the default value, in hexadecimal format, for the register at
power-on reset.
•
Description
: This field gives a bit definition (bit word name) and a description for
each bit in the register.