Microsemi Proprietary and Confidential. LX3301A/LX3302A Auto Calibration User Guide Revision 1.0
7
3
Data Preparation for IPCE
The following section describes how to prepare the data for IPCE.
IPCE supports analog, PWN, and SENT data formats.
The following image shows an example of the analog data format for analog output. It provides the data
format template.
Figure 9 • Analog Data Format for Analog Output
The following image describes the data format for analog data.
Figure 10 • Data Format for Analog Data
SP position—Start point position on the data (target position). See the red arrow.
EP position—End point position on the data. See the blue arrow.
SP AOUT(V)—Start point AOUT voltage (for example, 0.5). See the green arrow.
EP AOUT(V)—End point AOUT voltage (for example, 4.5). See the purple arrow.
VIN—VIN voltage supplied to the sensor board.
A_Tolerance (V)—Allowable tolerance for auto calibration.
The following list describes data preparation using the Excel data template.
Position value must be arranged lowest to highest value (no negative slope).
SP_AOUT—Must be a low setting value.
EP_AOUT—Must be a high setting value.