Setting Up Partial Scan
System Components
2
HAWK MV-4000 Smart Camera Guide
2-51
Setting Up Partial Scan
Sensor WOI Limitations
The combination of
X Offset
and
Y Offset
determines the location of the
top left corner
of the window of interest (WOI).
Stride
determines the width of the WOI.
Rows
determines the height of the WOI.
All the highlighted fields shown in the example above
must
be changed when creating a
partial scan camdef. The file name must also be changed, showing the WOI size in the name.
•
X Offset:
This value must be a multiple of 32.
•
Y Offset:
This value must be a multiple of 2.
•
Stride:
This value must be a multiple of 32.
•
Rows:
This value must be a multiple of 2.
Minimum size X of 32. Maximum value to whole sensor size.