MicroPower SMP 120/10 User Manual Download Page 7

 

 

 

 

 

 
 
 
Action to be taken: 

 

1.

 

Connect the SMP to the battery using the supplied cables and switch on the charger using the 
switch on the back. 

2.

 

Adjust the voltage level to 67,2 V using the 

VOLTAGE

 knob. 

3.

 

Adjust the current level to 4,0 A using the 

CURRENT

 knob. 

 
Note! Please have in mind that this charger will limit the output power to 800W. 
 
The top display will now show the actual voltage level that slowly will increase towards the adjusted 
level of 67,2 V, however only in very rare cases. In the meantime the lower display will show the 
adjusted current level of 4,0 A. To verify the set values, press the 

SET

 button. 

 
The de-sulphating process is only ready when battery voltage and specific gravity is stabilised. In 
cases when only the weekends are available for de-sulphating you can continue the following 
weekend. 
 
If you require any further information or assistance please do not hesitate to contact the local 
Micropower representative or Micropower directly. 
 
 

 

 

Technical Specification 

Mains supply: 

 220-240VAC 50-60Hz (90-200 power limited)  

Current draw: 

4,5A 

Power factor:  

~1 (PFC) 

 
 

 

 

 

 
 
Max. Power: 800W 
Max. Ripple out: 

30mV RMS 

Efficiency:   

>86% 

Frequency:   

>100kHz 

Cooling: 

 

Temp. Controlled fan 

Weight: 

 

1,6kg 

Dimension:   

258 x 136 x 89mm 

Protection:   

IP21, Electrically II (with or 
Without earth. 

 
Cables: 

 

One set of laboratory cables 

 

 

Is included. 

 
 

9904111 Issue 4 

 

120/10 

Max. Current: 

10A 

Max. Voltage: 

120V 

 

Summary of Contents for SMP 120/10

Page 1: ...anvisning S 2 User Manual GB 5 Bedienungsanleitung D 8 Mode d emploi F 11 Micropower E D AB Tel 46 0 470 727400 Fax 46 0 470 727401 Idav gen 1 SE 352 46 V xj sales micropower se www micropower se Swed...

Page 2: ...tsp nningen och tillkalla servicepersonal I laddaren finns sp nning som kan orsaka personskada Kapslingen f r d rf r endast ppnas av beh rig servicepersonal Vid laddning av batterier sker v tgasutveck...

Page 3: ...st llningsratt m rkt CURRENT tills nskad utstr m visas p display Sp nningsgr ns H ll in SET samtidigt som nskad sp nningsgr ns injusteras med VOLTAGE Str mgr ns H ll in SET samtidigt som nskad str mgr...

Page 4: ...en kan anses vara klar n r battericellernas sp nning resp syravikt ej forts tter att stiga Om man inte har tillr cklig tid kan det nd vara ide att rekonditioneringsladda ver ett veckoslut f r att seda...

Page 5: ...age immediately and send for service personnel The charger has a voltage that can cause personal injury Thus the metal casing may only be opened by authorised service personnel Hydrogen gas is generat...

Page 6: ...rn the knob marked VOLTAGE to the required voltage level Current Limit Turn the knob marked CURRENT to the required current level Voltage Press the SET button to see the adjusted voltage level Current...

Page 7: ...alues press the SET button The de sulphating process is only ready when battery voltage and specific gravity is stabilised In cases when only the weekends are available for de sulphating you can conti...

Page 8: ...ile Schalten Sie die Stromversorgung unverz glich ab und rufen Sie das Wartungspersonal Die Spannung des Batterieladeger ts kann Verletzungen verursachen Daher darf das Metallgeh use nur von autorisie...

Page 9: ...auf den gew nschten Spannungswert Stromst rkebegrenzung Stellen Sie den Drehregler CURRENT auf den gew nschten Stromst rkewert Spannung Dr cken Sie die Taste SET um den eingestellten Spannungswert anz...

Page 10: ...ke Dr cken Sie die Taste SET um die Vorgabewerte zu best tigen Die Desulfatierung ist erst abgeschlossen wenn sich Batteriespannung und spezifisches Gewicht stabilisiert haben Wenn f r eine Desulfatie...

Page 11: ...ement et contactez un proessionnel de service La tension produite par le chargeur de batterie peut tre cause de blessures corporelles Par cons quent le bo tier en m tal ne peut tre ouvert que par un p...

Page 12: ...ichage soit visible Limite de tension Tournez le bouton marqu VOLTAGE sur le niveau de tension souhait Limite de courant Tournez le bouton marqu CURRENT sur le niveau de courant souhait Tension Appuye...

Page 13: ...uration n est termin que lorsque la tension de la batterie et la densit relative se sont stabilis es Dans les cas o la d sulfuration ne peut tre effectu e que durant le week end vous pouvez continuer...

Reviews: