8.11 Menu 10
-
PELLET TYPE
Pressing P1 or P2 will modify the pellet loading percentage (
figure 49
) up to a maxi-
mum value of +9 and down to a minimum value of
-
9. Each step increases or decreases
it by around 3% of the total period of the feed screw, with respect to the default period
(pellet type = 0). The T
-
ON AUGER time does not change.
8.10 Menu 09
-
TECHNICAL SETTINGS
This item in the menu is accessible only to the technician who installed the heater. Once
the access key
A9
is entered (
figure 48
), it allows you to set the various parameters of the
heater
’
s operation by pressing P1 (to go up) and P2 (to go dowm).
figure 48
figure 49
8.11 Menu 10
-
CHIMNEY TYPE
Pressing P1 or P2 will modify the fumes velocity percentage (
figure 50
) up to a maxi-
mum value of +9 and down to a minimum value of
-
9. Each step increases or decreases
it by around 5% of the total velocity of the smoke fan
figure 50