Control board O047+T047idro
Micronova
page 29 of 113
ENG
OPERA
TING M
ODE
VISUALIZED SET ON DISPLAY BY USER
ACTIVE
MODE
M
-
9
-
2
-
15
CONTACT PRE-
SENT
SAMPLE VI-
SUALIZATION
ON DISPALY
DESCRIPTION
RISC
(1)
NONE
21°C AIR
70°C P
-
2
ALTERNATE VISUALIZATION:
-
ROOM TEMPERATURE PROBE
-
WATER PROBE AND POWER OF STOVE
FLOW METER
21°C AIR
70°C FLUS
ALTERNATE VISUALIZATION:
-
ROOM TEMPERATURE PROBE
-
WATER PROBE AND CALLING FLOW
METER
T
-
E CONTACT
T
-
E AIR
70°C P
-
2
ALTERNATE VISUALIZATION:
-
CONTACT AMBIENT THERMOSTAT
-
WATER PROBE AND POWER OF STOVE
T
-
E CONTACT
+
FLOWMETER
T
-
E AIR
70°C FLUS
ALTERNATE VISUALIZATION:
-
AMBIENT THERMOSTAT CONTACT
-
SONDA ACQUA E FLUSSATO IN CHIA-
MATA
PUFF
(1)
NONE
16.5°C PUFF
70°C P
-
4
ALTERNATE VISUALIZATION:
-
PUFFER PROBE
-
WATER PROBE AND POWER OF STOVE
BOILER
(1)
NONE
21°C AIR
60°C BOIL
40°C P
-
4
ALTERNATE VISUALIZATION:
-
ROOM TEMPERATURE PROBE
-
WATER PROBE BOILER
-
WATER PROBE AND POWER OF STOVE
P
-
TE
(2)
T
-
E CONTACT
T
-
E PUFF
40°C P
-
4
ALTERNATE VISUALIZATION:
-
PUFFER THERMOSTAT CONTACT
-
WATER PROBE AND POWER OF STOVE
(1) IF THERE
’
S MOUNT A AMBIENT THERMOSTAT ( T
-
E=TERM EXT OPT ) ON THE DISPLAY A SEG-
MENT ABOVE THE CLOCK ICON APPEARS.
(2) IN THE P
-
TE ACTIVE MODE, T
-
E CONTACT IS THE PUFFER THERMOSTAT
POMPA
MODULAZIONE
STANDBY
ON: IF WATER PROBE
HEATER > 85°C
FORCED IF
FLUE PROBE >
M
-
9
-
4
-
14
FORCED IF
WATER PRO-
BE HEATER >
85°C
ON: IF WATER PROBE
HEATER< 5°C
ON FOR 1 min: IF STOVE
OFF FOR 24H
N.B.
Below is a summary table of forced activations of outputs or functions during both
work and off, which the controller operates for safety reasons in complete autonomy wi-
thout parameters that can be set: