background image

PPS-60

 

Precision Positioner Stage

 

 

 
 

 

Rev: 1.04 

 

MICRONIX USA,LLC 

 Irvine, California 

www.micronixsusa.com 

 

32  

Reference Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 

External Stepper Motor Connector Pinout 

Description 

Color 

L1 

L2 

L3 

L4  

L5 

L6 

Motor Phase A+ 

Red 

8  (Brwn & Brwn Wht TP) 

 

Motor Phase B+ 

Green 

7  (Violet & Violet Wht TP) 

 

Limit  

White 

6  (Blue) 

 

Enc Shield 

Shield 

5 (Shield) 

Casing 

 

+5V 

Red 

4 (Red) 

 

Index+ 

Violet 

3  (Violet)  

 

Cos+ 

Brown 

2  (Brown) 

 

Sin- 

Green 

1  (White - Yellow TP) 

 

Motor Phase A- 

Blue 

15 

15 (Grn & Grn Wht TP) 

 

Motor Phase B- 

Black 

10 

10 

14 

14 (Yellow & Yellow Wht TP) 

 

Limit Switch- 

Violet 

11 

11 

13 

13 (White - Blue TP) 

 

Ground 

Brown 

Black 

12 

12 

12  

12 (Black/Black) 

Index- 

Blue 

13 

13 

11 

11  (White - Violet TP) 

 

Cos- 

Orange 

14 

14 

10 

10  (White - Brown TP) 

 

Sin+ 

Yellow 

15 

15 

9  (Yellow) 

 

 
 
 
 
 
 
 
 
 

A.6.8

 

Straight Through 15-Pin Feed Through 

 

 

-Encoder 

 

-Motor 

External Version 

Summary of Contents for PPS-60 Series

Page 1: ...S e r i e s Reference Manual Precision Positioner Stage Open and Closed Loop Versions PPS 60...

Page 2: ...S 60 Precision Positioner Stage Reference Manual Rev 1 04 MICRONIX USA LLC 15375 Barranca Parkway E 106 Irvine CA 92618 Tel 949 480 0538 Fax 949 480 0538 Email info micronixusa com http micronixusa co...

Page 3: ...ing 11 5 Connecting the PPS 60 12 5 1 Atmospheric Environments 12 5 1 1 Open Loop Installation Wiring Diagram 12 5 1 2 Closed Loop Encoder Installation Wiring Diagram 13 5 1 Vacuum Environments 15 5 1...

Page 4: ...Overview 30 A 6 2 Encoder Pin out 30 A 6 3 Operating and Electrical Specifications 30 A 6 4 Analog Output Pins 1 2 6 and 7 30 A 6 5 Index Window Pins 3 30 A 6 6 Resolution 30 A 6 7 Analog Encoder Wiri...

Page 5: ...Product Description The PPS 60 is a high precision linear stage which incorporates stepper piezo or linear motors into the same form factor Precision ball bearings assure high stiffness and guiding a...

Page 6: ...00 100 SM 001 internal 10 100 150 10 10 10 100 100 SM 003 external 10 100 150 10 10 10 100 100 LM 002 10 100 150 10 10 10 100 100 Motor option PM 003 SM 001 SM 003 LM 002 Speed max mm sec 10 10 15 100...

Page 7: ...option 3 digital encoder Only available with Piezo motor option or externally mounted UHV stepper motor Not available in vacuum environments Only available with Piezo motor Contact MICRONIX USA for c...

Page 8: ...be within specification at 20 C 5 C unless otherwise specified The operating conditions of the stage are as follows Mount to a clean and flat surface which is free of debris burrs and dings An indoor...

Page 9: ...ess base mounting pattern Note that the 25mm version can only be mounted using the M4 Bottom Mount method Please note it is possible to move the carriage of the linear and piezo motor configurations m...

Page 10: ...a www micronixsusa com 8 Reference Manual 4 1 1 2 Metric Mounting M4 Bottom Mount Travel A mm 25mm 75 50mm 75 100mm 125 200mm 225 300mm 325 Metric M4 Bottom Mount Mounting Pattern Requires 2 x M2 x 6m...

Page 11: ...s of the optical table for precision fit wFor internal motor configurations Mounting screws must be flush with base surface Travel A mm 25mm 75 50mm 75 100mm 125 200mm 225 300mm 325 Requires 2x M2 x 6...

Page 12: ...screws must be flush with base surface Travel A mm in 25mm 50 8 2 50mm 50 8 2 100mm 101 6 4 200mm 203 2 8 300mm 304 8 12 Imperial Base Mounting Pattern Requires 2 x M2 x 6mm Dowel Pins 4 x 4 40 Pan H...

Page 13: ...e note that it is possible to move the carriage of the linear and piezo motor configurations manually without damaging the stage however for stepper versions the motor must be driven by a controller t...

Page 14: ...nt for all piezo stepper and linear motor assemblies 5 1 1 Open Loop Installation Wiring Diagram Connecting the PPS 60 in an open loop configuration only requires that the D sub 9 Pin Motor Cable be c...

Page 15: ...d Loop Encoder Installation Wiring Diagram Using the PPS 60 stage with an encoder requires a closed loop compatible controller that recognizes the proper type of encoder feedback Connect the stage as...

Page 16: ...ion Positioner Stage Rev 1 04 MICRONIX USA LLC Irvine California www micronixsusa com 14 Reference Manual 5 1 2 2 MII 6000 Digital Encoder Wiring Diagram Internal Piezo Linear and Stepper Versions Ext...

Page 17: ...MII 6000 digital encoder 5 1 2 Open loop Installation Wiring Diagram Connecting an open loop PPS 60 in a vacuum chamber requires the use of a feed through connector at the vacuum chamber wall The vac...

Page 18: ...er cable The vacuum compatible PPS 60 will be supplied with wiring for a straight through feed through not a cross over gender bender MICRONIX USA supplies test connectors that simulate the vacuum fee...

Page 19: ...A LLC Irvine California www micronixsusa com 17 Reference Manual 5 1 3 2 MII 6000 Digital Encoder Wiring Diagram Internal Piezo and Stepper Versions External Version Temporary test connectors are stan...

Page 20: ...X USA LLC Irvine California www micronixsusa com 18 Reference Manual 6 Dimensions 6 1 PPS 60 Internal Motor Versions Travel mm A mm B mm C mm D mm 25 117 95 50 8 75 50 142 120 50 8 75 100 192 170 101...

Page 21: ...itioner Stage Rev 1 04 MICRONIX USA LLC Irvine California www micronixsusa com 19 Reference Manual 6 2 PPS 60 External Stepper Motor Versions Travel mm A mm B mm C mm 100 75 170 247 6 200 175 270 347...

Page 22: ...guration Examples Additional configurations available upon request Note Stacking compatibility for all motor configurations Positioning according to No Adapters X Y 50x50mm X Y 200x50mm X Y Off Center...

Page 23: ...Manual X Y 100x26mm with PPS 28 Linear Stage X Y Z 100x26x35mm with PPS 28 Linear Stage PZS 90 Elevation Stage X Y Z 200x26x35mm with PPS 28 Linear Stage PZS 90 Elevation Stage Using Adapter Block P...

Page 24: ...MICRONIX USA LLC Irvine California www micronixsusa com 22 Reference Manual Using Z Bracket P N 430613 X Y 200x100mm X Y Z 50x50x100mm Using XY Bracket P N 430169 VT 21 Linear Stages X Y 100x10mm X Y...

Page 25: ...inate the lubrication and jeopardize the longevity of the stage Follow the Installation Preparation requirements and use proper cable management to ensure a clean and safe operating environment 8 2 Un...

Page 26: ...or A Blue 3 Motor B Green 4 Motor B Black Red 5 Limit Switch GND Brown Brown 6 Limit Switch White Violet 7 Limit Switch Violet White 8 N C N C N C 9 N C N C N C White motor wire may be changed to gree...

Page 27: ...A Red 2 B Black 3 C White 4 N C N C 5 Limit Switch GND Brown 6 Limit Switch White 7 Limit Switch Violet 8 N C N C 9 N C N C Linear Motor Continuous Force 2 7 N Continuous Current 0 8 Arms Acceleratio...

Page 28: ...ce Manual A 3 Piezo Motor A 3 1 Standard Atmospheric DB 9 Male Motor Connector A 3 2 2 Phase Piezo Motor Wiring Connections Piezo Motor Pin Function Wire Color 1 Phase 1 Red 2 Phase 2 Yellow 3 N C N C...

Page 29: ...prevent the carriage from running away should the limit switches fail The mechanical limit switches are factory calibrated to ensure advertised travel length and cannot be adjusted by the customer Op...

Page 30: ...L5 Phase 1 Red 5 5 1 1 1 Phase 2 Yellow 4 4 2 2 2 Limit Switch Violet 8 8 7 7 7 Motor Ground Green Blk 1 1 5 5 5 Limit Ground Brown 7 7 8 8 8 Limit Switch White 9 9 6 6 6 Motor Internal Stepper Motor...

Page 31: ...er Motor Connector Pinout Description Color L1 L2 L3 L4 L5 Motor Phase A Red 5 5 1 1 Red 1 Motor Phase B Green 3 3 3 3 Green 3 Limit Switch White 9 9 6 6 White Violet TP 6 Motor Phase A Blue 4 4 2 2 B...

Page 32: ...acuum connector that incorporates both motor and encoder signals along with an atmospheric cable splitting the signals into separate 9 pin connectors motor connector and encoder connector A 6 2 Encode...

Page 33: ...et 6 6 3 3 Violet 3 Cos Brown 7 7 2 2 Brown 1 Sin Green 8 8 1 1 White Yellow TP 7 Motor Ground Green Blk 9 9 15 15 Green Black 2 Enc Ground Black 12 12 12 12 Black 4 Index Blue 13 13 11 11 White Viole...

Page 34: ...Shield Shield 4 4 5 5 Shield Casing 5V Red 5 5 4 4 Red 5 Index Violet 6 6 3 3 Violet 3 Cos Brown 7 7 2 2 Brown 1 Sin Green 8 8 1 1 White Yellow TP 7 Motor Phase A Blue 9 9 15 15 Grn Grn Wht TP 2 Motor...

Page 35: ...cates misalignment of the Encoder Head if this occurs contact MICRONIX USA Do not adjust the Encoder Head or scale For more information refer to MicroE Systems Mercury Encoders A 7 1 36BEncoder Module...

Page 36: ...he index pulse may be aligned with other states of A or B than the ones shown Above are with reference to the sensor s optical centerline A 7 4 Resolution All closed loop stages are supplied with 20 m...

Page 37: ...Blue TP nSS Green 8 8 6 6 Green nSS White Green TP 21 21 18 18 White Green TP CLK Brown 9 9 5 5 Brown CLK White Brown TP 22 22 17 17 White Brown TP Shield Shield 16 16 23 N C Internal Stepper Motor C...

Page 38: ...witch Violet 16 16 23 23 Violet 7 Motor Phase B Black 4 4 10 10 Black 4 Shield 5 5 9 9 Shield Casing 5VDC Red 8 8 6 6 Red GND Black 20 20 19 19 Black DCLK Gray 9 9 5 5 Gray DCLK White Gray TP 21 21 18...

Page 39: ...off when passing over index Yellow alignment not optimal but encoder counting integrity is still good Red alignment poor discontinue use and realign sensor to scale Technical Specifications Resolution...

Page 40: ...LLC Irvine California www micronixsusa com 38 Reference Manual A 8 3 Operating and Electrical Specifications A 8 4 Output Signals Power Supply 5VDC 5 95mA 40mA for sensor Operating Temperature 0 to 7...