PPS-60
Precision Positioner Stage
Rev: 1.04
MICRONIX USA,LLC
Irvine, California
www.micronixsusa.com
7
Reference Manual
4.
Installing the PPS-60
Mounting patterns require M3, M4, or 4-40 socket head cap screws or pan head
machine screws for mounting, as well as M2 x 6mm dowel pins for precision alignment.
Additional brackets and screws may be required for custom applications.
4.1
PPS-60 Installation
4.1.1
General Mounting
For general mounting configurations, mount the base to the mounting surface
using the thru holes. Move the carriage to access base mounting pattern. Note
that the 25mm version can only be mounted using the M4 Bottom Mount
method. (Please note, it is possible to move the carriage of the linear and piezo
motor configurations manually without damaging the stage, however, for
*stepper versions the motor must be driven by a controller to reposition the
carriage.)
4.1.1.1
Metric Mounting: M3 Top Mount
Travel
A
[mm]
25mm
75
50mm
75
100mm
125
200mm
225
300mm
325
Requires:
2x M2 x 6mm Dowel Pins
4x M3 Socket Head Cap Screws
(Low Profile recommended)
1. Move carriage via controller*, if
necessary, to access four
mounting holes. Insert Pins and M3
SHCS as shown.
Metric M3 Top Mount Mounting Pattern
w
For internal motor configurations: Mounting screws must be flush with base surface.