Microlife NC 200 Manual Download Page 5

5

NC 200

EN

starts to flash 

BO

. Now you can enter the new values as 

described above.

Setting the beeper

1. Press and hold the MODE button

6

 for 3 seconds to set the 

beeper 

BP

.

2. Press the M-button

5

 to either turn the beeper on or off. The 

beeper is activated when the beeper icon 

BP

 is shown without 

a cross.

When the beeper setting has been chosen, press the 

START/IO button 

7

 to enter the «ready for measuring» 

mode; otherwise the device automatically switches to ready 

for measuring after 10 seconds 

AT

.

6. Changing between Body and Object Mode

1. Press the START/IO button 

7

. The display 

4

 is activated to 

show all segments for 1 second.

2. The default mode is body mode 

AL

. Press the MODE button

6

 

to switch to object mode 

AM

. For switching back to body mode, 

press the MODE button again.

7. Directions for Use

Always remove the protective cap 

BS

 before use.

Measuring in body mode with auto measurement and 

distance control

1. Press the START/IO button 

7

. The display 

4

 is activated to 

show all segments for 1 second.

2. A flashing «

°C

»/«

°F

» icon, the blinking blue tracking light 

2

 and 

a beep indicate that the device is ready for measurement 

AT

.

3. Remove any hair, sweat or dirt from the forehead before 

measuring to ensure the accuracy of the readings.

4.

Aim the thermometer at the center of the forehead with a 

distance of no more than 5 cm.

5.

The device will start the measurement automatically, when 

the measuring sensor 

1

 detects the distance is appropriate 

within 5 cm.

 The display will show a countdown (3, 2, 1); after 

3 seconds a long beep will verify the completion of measurement.

6.

Self-measurement:

 The green self-indicator light 

3

 will help 

to distinguish the start of the measurement. Keep the thermom-

eter pointed towards the forehead until the light switches off.

7. Read the recorded temperature from the LCD display.

8. For the next measurement remove the thermometer from the 

forehead and wait until the «

°C

»/«

°F

» icon is flashing. Follow 

steps 4-5 above.

9. Press and hold the START/IO button 

7

 for 3 seconds to turn 

off the device; otherwise the device will automatically switch off 

after approx. 60 seconds.

Measuring in object mode without auto measurement 

1. Press the START/IO button 

7

. The display 

4

 is activated to 

show all segments for 1 second.

2. Press the MODE button

6

 to switch to object mode.

3. A flashing «

°C

»/«

°F

» icon, the blinking blue tracking light 

2

 and 

a beep indicate that the device is ready for measurement 

AT

.

4. Aim the thermometer at the center of the object you want to 

measure with a distance of no more than 5 cm. 

Press the 

START/IO button 

7

.

 After 3 seconds a long beep will verify 

the completion of measurement.

5. Read the recorded temperature from the LCD display.

6. For the next measurement wait until the «

°C

»/«

°F

» icon is 

flashing and follow steps 4-5 above.

7. Press and hold the START/IO button 

7

 for 3 seconds to turn 

off the device; otherwise the device will automatically switch off 

after approx. 60 seconds.

NOTE:

Patients and thermometer should stay in similar room 

condition for at least 30 minutes.

Don't take a measurement while or immediately after nursing a 

baby.

Don't use the thermometer in high humidity environments.

Patients should not drink, eat or exercise before/while taking 

the measurement.

Don't move the measurement device from the measuring area 

before hearing the termination beep.

10 short beeps and a red LCD backlight alert the patient that he/

she may have a temperature equal to or higher than 37.5 °C.

Always take the temperature in the same location, since 

temperature readings may vary according to locations.

Doctors recommend rectal measurement for newborn infants 

within the first 6 months, as all other measuring methods might 

lead to ambiguous results. If using a non contact thermometer 

on those infants, we always recommend verifying the readings 

with a rectal measurement.

Summary of Contents for NC 200

Page 1: ...enstrasse139 9443Widnau Switzerland 139 9443 ONBOElectronic Shenzhen Co Ltd No 138 HuashengRoad LangkouCommunity DalangStreet Longhua District Shenzhen China No 138 41717277000 41717277001 admin micro...

Page 2: ...ty information Microlife Non Contact Thermometer NC 200 EN 1 Measuring sensor 2 Tracking light 3 Self indicator light 4 Display 5 M button memory 6 MODE button 7 START IO button 8 Battery compartment...

Page 3: ...0 1 99 9 C 32 2 211 8 F meaning the unit can be used to measure body temperature or it also has a feature allowing it to be used to measure surface temperature of the following examples Milk surface t...

Page 4: ...or an ambulance is advised if needed 3 How this Thermometer measures Temperature This thermometer measures infrared energy radiated from the forehead as well as objects This energy is collected throug...

Page 5: ...display 8 For the next measurement remove the thermometer from the forehead and wait until the C F icon is flashing Follow steps 4 5 above 9 Press and hold the START IO button 7 for 3 seconds to turn...

Page 6: ...yed Pressing and releasing the M button 5 after the last 30 readings have been recalled will resume the above sequence from reading 1 10 Error Messages Measured temperature too high AR Displays H when...

Page 7: ...al regulations Type Non Contact Thermometer NC 200 Measurement range Body mode 34 0 43 C 93 2 109 4 F Object mode 0 1 99 9 C 32 2 211 8 F Resolution 0 1 C F Measurement accuracy Laboratory Body mode 0...

Page 8: ...d pressure monitors as well as services can be found at www microlife com Date of production first six digitsof the serial number of the device First and second digit the year of production third and...

Page 9: ...9 NC 200 EN...

Page 10: ...10 BF Microlife Microlife 1 Microlife NC 200 RU 1 2 3 4 5 M 6 MODE 7 START IO 8 9 AT AK AL AM AN AO AP AQ 30 AR AS BT BK BL BM BN BO BP BQ BR BS SN N...

Page 11: ...11 NC 200 RU 2 3 4 5 6 7 8 9 30 10 11 12 13 14 15 www microlife ua 1 5 0 1 99 9 C 32 2 211 8 F y o 30 10 37 5 C 2...

Page 12: ...12 15 3 3 m 3 4 9 START IO 7 1 AT C F BR 3 3 2 1 AK 4 C F C F AN 5 1 BO 5 MODE 6 2 5 MODE 6 3 4 START IO 7...

Page 13: ...BO 1 MODE 6 3 BP 2 5 BP START IO 7 10 AT 6 1 START IO 7 4 1 2 AL MODE 6 AM MODE 7 BS 1 START IO 7 4 1 2 C F 2 AT 3 4 5 5 1 5 3 2 1 3 6 3 7 8 C F 4 5 9 START IO 7 3 60 1 START IO 7 4 1 2 MODE 6 3 C F 2...

Page 14: ...97 9 100 4 F Microlife NC 200 35 4 37 4 C 95 7 99 3 F 8 C F MODE 6 3 MODE C F AO C F M 5 START IO 7 10 AT 9 30 30 AP M 5 M 1 AQ M 5 1 M 5 30 1 10 AR H 43 C 109 4 F 99 9 C 211 8 F AS L 34 C 93 2 F 0 1...

Page 15: ...rolife www microlife com support 14 NC 200 34 0 43 C 93 2 109 4 F 0 1 99 9 C 32 2 211 8 F 0 1 C F 0 2 C 35 0 42 0 C 0 4 F 95 0 107 6 F 0 3 C 34 0 34 9 C 42 1 43 0 C 0 5 F 93 2 94 8 F 107 8 109 4 F 1 0...

Page 16: ...www microlife ua 30 1 37 5 C 99 5 F 5 37 5 C 99 5 F 5 15 40 0 C 59 104 0 F 5 40 0 C 41 104 0 F 25 55 C 13 131 F 15 95 1 2 x 1 5V AAA 2000 156 7 x 43 x 47 mm 91 5 68 5 IP22 ASTM E1965 IEC 60601 1 IEC 6...

Page 17: ...17 NC 200 RU...

Page 18: ...18 BF Microlife o Microlife Microlife NC 200 UA 1 2 3 4 5 M 6 MODE 7 STAR IO 8 9 AT AK AL P AM P AN AO AP AQ 30 AR AS BT BK BL BM BN BO BP BQ BR BS e CE SN N...

Page 19: ...19 NC 200 UA 1 2 3 4 5 6 7 8 9 30 10 11 12 13 14 15 www microlife ua 1 5 sm 0 1 99 9 C 32 2 211 8 F 30...

Page 20: ...20 10 37 5 C 2 15 3 3 m 3 4 9 START IO 7 1 AT C F BR 3 3 2 1 AK 4 C F C F...

Page 21: ...ODE 6 3 4 START IO 7 20 AT 7 START IO 7 30 MODE 6 8 BO 1 MODE 6 3 BP 2 M 5 BP START IO 7 10 AT 6 1 START IO 7 4 1 2 AL MODE 6 AM MODE 7 BS 1 START IO 7 4 1 2 C F 2 AT 3 4 5 sm 5 1 5 sm 3 2 1 3 6 3 7 8...

Page 22: ...C F 4 5 7 START IO 7 3 60 30 10 37 5 C 6 1 2 3 34 7 37 3 C 94 5 99 1 F O 35 5 37 5 C 95 9 99 5 F P 36 6 38 0 C 97 9 100 4 F Microlife NC 200 35 4 37 4 C 95 7 99 3 F 8 C F MODE 6 3 MODE C F AO C i F M...

Page 23: ...1 10 AR H 43 C 109 4 F 99 9 C 211 8 F AS L 34 C 93 2 F 0 1 C 32 2 F BT AH 40 C 104 0 F BK AL 15 C 59 F 5 0 C 41 0 F BL Er 0 Er 6 Er 2 1 5 sm BM BN 11 70 y 12 2 1 5 CR2032 BN BQ 13 5 Microlife Microli...

Page 24: ...7 6 F 0 3 C 34 0 34 9 C 42 1 43 0 C 0 5 F 93 2 94 8 F 107 8 109 4 F P 1 0 C 0 100 0 C 2 F 32 0 212 F 4 1 1 1 37 5 C 99 5 F 10 37 5 C 99 5 F 3 30 1 37 5 C 99 5 F 5 37 5 C 99 5 F 5 15 40 0 C 59 104 0 F...

Page 25: ...25 NC 200 UA...