ULM–70
© Dinel, s.r.o.
31
A
reA
cLAssificAtion
(according to EN 60079-10 and EN 60079-14)
ULM–70N–_ _
Performance for non-explosive areas
ULM–70Xi–02
ULM–70Xi–06
Explosive proof – suitable for explosive areas (combustible gases or vapours)
II 1/2G Ex ia IIB T5 Ga/Gb with Isolating repeater (IRU–420), the whole level meter
– zone 1, front head part – zone 0
ULM–70Xi–10
Explosive proof – suitable for explosive areas (combustible gases or vapours)
II 1/2G Ex ia IIA T5 Ga/Gb with Isolating repeater (IRU–420), the whole level meter
– zone 1, front head part – zone 0
ULM–70Xi–20
Explosive proof – suitable for explosive areas (combustible gases or vapours)
II 2G Ex ia IIA T5 Gb with Isolating repeater (IRU–420), the whole level meter – zone 1
Used symbols
To ensure maximum safety of control processes, we have defined the following safety instructions
and information. Each instruction is labeled with the appropriate pictogram.
Alert, warning, danger
This symbol informs you about particularly important instructions for installation and op-
eration of equipment or dangerous situations that may occur during the installation and
operation. Not observing these instructions may cause disturbance, damage or destruction
of equipment or may cause injury
Information
This symbol indicates particularly important characteristics of the device.
Note
This symbol indicates helpful additional information.
21 . Packaging, shipping and storage
The device DLM–35 is packaged in a polyethylene bag, and the entire consignment is placed into a
cardboard box. A suitable filler material is used in the cardboard box to prevent mechanical damage
during transport. Remove the device from the packaging only just before using, thereby protecting it
from potential damage.
A forwarding company will be used to ship goods to the customer. Upon prior agreement, ordered goods
can be picked up in person at company headquarters. When receiving, please check to see that the
consignment is complete and matches the order, or to see if any damage has occurred to the packaging
and device during transport. Do not use a device clearly damaged during transport, but rather contact
the manufacturer in order to resolve the situation.
If the device is to be further shipped, it must be wrapped in its original packaging and protected against
impact and weather conditions.
Store the device in its original packaging in dry areas covered from weather conditions, with humidity
of up to 85 % without effects of chemically active substances. The storage temperature range is -20°C
to +60°C.
Level meters of variants ULM–53_– 02, 06, 10 are fitted with protective caps to prevent
damage to the ultrasonic transducer.
Remove the cover prior to putting into operation.