![Microlectra Dinel ULM-70 Instruction Manual Download Page 22](http://html1.mh-extra.com/html/microlectra/dinel-ulm-70/dinel-ulm-70_instruction-manual_1786790022.webp)
22
©
Dinel, s.r.o. ULM–70
C L O N E S E T T I N G S
W A R N I N G – C L O N I N G I S N O T
P O S S I B L E
W R O N G S E N S O R T Y P E
P R E S S
E S C
T O E X I T
C L O N E S E T T I N G S
W A R N I N G – C L O N I N G I S N O T
P O S S I B L E
N O S E T T I N G S S A V E D
P R E S S
E S C
T O E X I T
Incompatible type of level meter. Transfer of the settings can be
realized only with the same type of level meter (e.g. ULM–70–02
- ULM–70-02, ULM–70–10 - ULM–70–10) and with the firmware
version 2.0 and later.
PASSWORD
You can
lock
the level meter data against
unauthorized editing
.
After activating the password the data may be read, but can not be
edited. If you try to edit the settings (without true password) the
display shows "NO PASSWORD".
The password can be any 5-digit numeric combination. The com
-
bination of numbers 00000 is reserved for disabling the password.
1.
Use the buttons
and
in the menu "PASSWORD" to select the mode "ENTER" for en
-
tering the password or the mode "CHANGE" for changing the password (when activated,
the words are displayed inversely). Press the button
once again to confirm the selec
-
tion. You can change the password only when the level meter is unlocked. Otherwise, the
words "NO PASSWORD" will be displayed.
2.
Now you can edit the password. The actual edited item is displayed inversely. Press the but
-
ton
to move to the next position (clockwise direction), button
serves to change the
values (0 ... 9).
3.
After the operation is completed, confirm the edited data by pressing the button
.
Display of status information to con
-
firm data:
"YES" – correctly edited password
"NO" – incorrectly edited password
"OK" – the password saved (only in
case of "CHANGE")
The password is automatically hidden
after it is edited or changed ("00000"
will appear).
To deactivate the password, edit the
numerical combination "00000" in the
mode "CHANGE".
T E A C H I N G
S E T L E V E L D I S T A N C E :
0 6 0 0 0 m m
S T A R T
N O P A S S W O R D
P A S S W O R D
E N T E R
0 0 0 0 0
P A S S W O R D
C H A N G E
0
0 0 0 0
The data set is not stored into the display module (DM–70). The
transfer can not be done. It is necessary to repeat the procedure
of the copying the settings in the mode "CLONE SETTINGS".
The level meter with activated password will be automatically locked after 5 minutes
of inactivity or after 5 min. from switching to measuring mode. Locking of level meter
is indicated in the lower left corner of the screen by the letter "L".
If the password is lost, contact the manufacturer.
B A S I C S E T T I N G S
S E R V I C E
D I A G N O S T I C
C L O N E S E T T I N G S
P A S S W O R D
L A N G U A G E
I N F O
Summary of Contents for Dinel ULM-70
Page 2: ......