© Microhard
93
5.0 AT Command Line Interface
5.2 AT Command Syntax
The follow syntax is used when issuing AT Commands on the pMDDL5824
-
All commands start with the AT characters and end with the <Enter> key
-
Microhard Specific Commands start with +M
-
Help will list top level commands (ATL will list ALL available AT Commands)
-
To query syntax of a command: AT+<command_name>=?
-
Syntax for commands that are used only to query a setting:
AT<command_name>
-
Syntax for commands that can be used to query
and
set values:
AT<command_name>=parameter1,parameter2,
…
(Sets Values)
AT<command_name>?
(Queries the setting)
Query Syntax:
AT+MSCNTO=? <Enter>
+MSCNTO:
Command Syntax: AT+MSCNTO=<Timeout_s>
Parameter:
<Timeout_s> 30 to 65535 in seconds, 0
-
Disable
OK
Setting a value:
AT+MSCNTO=600 <Enter>
OK
Query a setting:
AT+MSCNTO? <Enter>
+MSCNTO: 600 seconds
OK
A screen capture of the above commands entered into a unit is shown below:
Image 5
-
3: Telnet AT Command Syntax
Once AT commands are entered, they must be saved into the file system to enable the changes.
AT&W
Saves changes.
ATO or ATA
Exits the AT Command Line Interface, if used before AT&W,
changes are discarded.
Summary of Contents for pMDDL5824
Page 23: ...Microhard 23 3 1 1 pMDDL5824 OEM Mechanical Drawing 3 0 Hardware Features...
Page 24: ...Microhard 24 3 1 2 pMDDL5824 PCB PAD Placement 3 0 Hardware Features...
Page 29: ...Microhard 29 3 0 Hardware Features 3 2 1 pMDDL5824 Development Board Mechanical Drawings...
Page 30: ...Microhard 30 3 0 Hardware Features 3 2 2 pMDDL5824 Enclosed Mechanical Drawings...
Page 114: ...Microhard 114 Appendix B Sample Interface Schematic...