12
The
ARENA ULTRA SPOT
can be placed di-
rectly on the stage floor or rigged in any orien-
tation on a truss without altering its operation
characteristics (see the drawing).
The fixture’s base enables to be mounted in
two ways. Use the clamps with screws M10 or
M8 - check the base bottom.
Install a safety cable that can hold at least 10
times the weight of the fixture. (You must use
safety-ropes with screw-on carabines. Pull the
safety-rope through the hole on the bottom of
the base and over the trussing system etc. In-
sert the end in the carabine and tighten the
fixation screw).
Connection with the power supply
Connect the device to the power supply with the power-plug.
The occupation of the connection-cables is as follows:
The earth has to be connected!
In general, lighting effects should not be
connected to dimming-packs.
17
ENGLISH
Channel 15 - Shutter, Strobe
Channel 16 - Dimmer intensity
4.2 Function of the control channels - 8 bit protocol:
5. ADDRESSING
The Control Board on the top side of the
ULTRA SPOT
allows you to assign the DMX fixture
address, which is defined as the first channel from which the
ULTRA SPOT
will respond to the
controller.
If you set, for example, the address to channel 5, the
ULTRA SPOT
will use the channel 5 to
20 for control.
Please, be sure that you don’t have any overlapping channels in order to control each
ULTRA SPOT
correctly and independently from any other fixture on the DMX data link.
If two, three or more
ULTRA SPOT
are addressed similarly, they will work similarly.
For address setting follow this procedure:
1.
Switch on the
ULTRA SPOT
and wait until the fixture reset has f inished
("rSt"
is flashing at the display).
2.
Press the
[Mode]
key in order to access the main menu. Browse through the menu by pressing the
[Up] and [Down] keys until the display shows
"A001
". Confirm by pressing
[Enter]
key and the letter
"A"
w ill flash.
3.
Use the [Up] and [Down] keys to select the desired address.
4.
Confirm by pressing
[Enter]
or
[Mode]
to cancel.
Controlling:
After having addressed all
ULTRA SPOT
, you may now start operating these via your lighting
controller.
Note:
After switching on, the
ULTRA SPOT
will automatically detect whether DMX 512 data is
received or not. If there is no data received at the DMX-input, the display will start to
flash
"A001"
with actually set address.