background image

 

 

 

Microframe Corporation 

 

 

 

 

 

 

 

9

 

604 South 12

th

 Street 

Broken Arrow, OK  74012 
800-635-3811 
www.microframecorp.com 

 

 

 

 

 

 

Series 3500 

Visual-Pager® Display Detailed Operation 

Configuration, Mode Settings continued… 

 

o

 

Roll-Over Time Setting 

The Roll-Over Time is the length of  time each number in the display memory is shown before changing to the next 
number.    This  time  can  be  set  from  1  to  9  seconds.    To  set  this  time,  send  a  page  to  Pager  9999  with  the 
message 

“01_0X” where X is a number 1-9 representing the number of seconds.  If you set this option to 0, the 

display will only show the last number received. 
 

o

 

Auto Delete Setting 

The  display  can  be  set  to  automatically  delete  a  number  from  its  memory  after  a  preset time.    NOTE:  If  you 
have a MultiPage Transmitter, use the transmitter's auto delete rather than the display's auto delete time.  To 
set the auto delete time, send a page to Pager 9999 with the message 

“02_XX” where XX is a number from 1 

to 42 representing the number of minutes to wait before auto deleting. 
 

o

 

Chime Setting 

If  you  have  purchased  an  optional  triac  circuit,  it  can  be  activated  every  time  a  new  number  is  sent  to  the 
display.    The  duration  of  the  triac  output  can  be  controlled  by  changing  this  option.    To  change  this  option, 
send a page to 9999 with the message 

“03_XX” where XX is a number from 00 to 99 representing the number 

of 0.1 second intervals that you want the output to be on (i.e. 99=9.9 seconds).  Sending a 00 will cause the 
triac circuit to be disabled. 
 

o

 

Clear All Numbers Command 

There are occasions when you may want to clear all numbers from all displays.  To clear all numbers, send a 
page to P

ager 9999 with the message “99_98.” 

 

o

 

Reset Factory Defaults 

To change the display settings back to factory defaults send a page to P

ager 9999 with the message “99_99.” 

 

o

 

Using the Display with Alternate Transmitters 

The Visual-Pager® Display has been designed to work optimally with the MultiPage  Transmitter. However, in 
rare cases you may want to use the display with a transmitter other than the MultiPage.  If so, you can control 
the  display's  basic  functions  by  sending  pages  to  the  d

isplay’s  address  with  beep  types  and  messages  to 

control the function.   
Beep Type 

“4” enters the number contained in the message into the display.  

Beep Type 

“3” removes the number contained in the message from the display. 

Example:  to  add  "123"  to  display  ID  1500,  do  the  following.    Send  a  page  to  Pager  1500  with  beep  type  4, 
message 123. 

Summary of Contents for MultiPage B3011

Page 1: ...7013 Manual No B3011 7013 Updated 11 2019 Rev 1 4 Microframe Corporation 604 South 12th Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 www microframecorp com support microframecorp com ...

Page 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Page 3: ...cificationGuide Table of Contents MultiPage System Overview and Features 4 MultiPage System Instructional Diagram 5 MultiPage Transmitter Features and Operation 6 Visual Pager Display Detailed Operation 8 Slimline 2 Pager Operation 10 Appendix A Changing the transmitter type 12 Model 3500 Specifications 13 Multipage Transmitter Specifications 14 ...

Page 4: ... Visual Pager Display The Wireless UHF Visual Pager Display has been designed to receive signals from the MultiPage Transmitter The display is available in a 2 3 4 or 6 digit model each of which has 5 5 tall red LED numbers Numbers sent to the display will be saved and shown on both the transmitter and the display until manually deleted or auto deleted depending upon user preference To enter a num...

Page 5: ...Microframe Corporation 5 604 South 12th Street Broken Arrow OK 74012 800 635 3811 www microframecorp com Series 3500 ...

Page 6: ...n type in the desired value To return to the main options menu press ENTER Once options are set press SEND to save changes or CANCEL to discard changes Each of the eight options are described in detail below OPTION 1 Transmitter Rollover Time The Rollover Time is the amount of time that each number in the transmitter memory shows on the LCD screen before rotating to the next number For example wit...

Page 7: ... recommended that users do not change this setting If you change this number the display and pager settings will have to be changed accordingly NOTE Slimline Pager Baud Rate can be re programmed at the base station OPTION 7 Out of Range This feature works with Slimline pagers When the out of range option is activated the transmitter will periodically send a page telling everyone that they still ar...

Page 8: ...eady to communicate with a MultiPage Transmitter Base ID 0500000 Baud Rate 1200 The display will intelligently communicate with other settings by doing the following Press the button on the back of the display one time The display will show vertical bars Next page Pager number 1 with a beep type of 2 and message 7337 The display should change to horizontal bars to signify that it has learned the t...

Page 9: ... is sent to the display The duration of the triac output can be controlled by changing this option To change this option send a page to 9999 with the message 03_XX where XX is a number from 00 to 99 representing the number of 0 1 second intervals that you want the output to be on i e 99 9 9 seconds Sending a 00 will cause the triac circuit to be disabled o Clear All Numbers Command There are occas...

Page 10: ...n right Changing the Alert Mode Pagers may be programmed to respond to a page by a combination of vibrating flashing and beeping By default the pagers are programmed to flash and vibrate for 2 minutes See below to set a new alert mode Out of Range These pagers can be programmed to alert continuously once they get out of range of the transmitter To use this feature first activate the option on the ...

Page 11: ... Reserved When you have selected the option you want press PROG Setting Starting Pager Number You can change the starting pager number for this base station For instance starting with pager 31 for a secondary base station Put the base station in program mode and select the STNO option Press PROG Use the up down arrows to set your desired starting number Hold down the PROG button to save about 3 se...

Page 12: ...tters are now supported by the same hardware platform When you order a B3011 or B3611 it should come pre programmed to the correct type To change the transmitter type Unplug power While pressing 0 and buttons plug in power At the password prompt type 0320 Enter Select 1 3500 or 2 3600 Press Enter to save Appendix A Changing the Transmitter Type ...

Page 13: ...wer Requirements 2 9 watts 3 5 watts 4 6 watts 6 8 watts Weight 2 5 lbs 3 2 lbs 3 9 lbs 5 25 lbs Width A Dimension Inches 9 8 13 2 16 8 24 Width A Dimension Centimeters 24 9 cm 33 5 cm 42 7 cm 61 4 cm Features The Visual Pager displays are designed to work best with the Microframe MultiPage System The displays have two modes 1 As a Visual Pager the display will store and rotate up to 20 numbers at...

Page 14: ...ea Typically 1 2 miles indoors Max 2 miles Mounting Desk or Wall Mount Dimensions 9 5 x 6 x 2 5 Excludes antenna Max Numbers Shown on Display 20 Max Pagers in Re Page Queue 30 Features This transmitter is designed to work out of the box with Multipage displays and Slimline pagers Operation Mode 1 Using the MultiPage Transmitter simply type in a number and press ENTER to send that number to the dis...