Microframe Corporation
9
604 South 12
th
Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com
Series 3500
Visual-Pager® Display Detailed Operation
Configuration, Mode Settings continued…
o
Roll-Over Time Setting
The Roll-Over Time is the length of time each number in the display memory is shown before changing to the next
number. This time can be set from 1 to 9 seconds. To set this time, send a page to Pager 9999 with the
message
“01_0X” where X is a number 1-9 representing the number of seconds. If you set this option to 0, the
display will only show the last number received.
o
Auto Delete Setting
The display can be set to automatically delete a number from its memory after a preset time. NOTE: If you
have a MultiPage Transmitter, use the transmitter's auto delete rather than the display's auto delete time. To
set the auto delete time, send a page to Pager 9999 with the message
“02_XX” where XX is a number from 1
to 42 representing the number of minutes to wait before auto deleting.
o
Chime Setting
If you have purchased an optional triac circuit, it can be activated every time a new number is sent to the
display. The duration of the triac output can be controlled by changing this option. To change this option,
send a page to 9999 with the message
“03_XX” where XX is a number from 00 to 99 representing the number
of 0.1 second intervals that you want the output to be on (i.e. 99=9.9 seconds). Sending a 00 will cause the
triac circuit to be disabled.
o
Clear All Numbers Command
There are occasions when you may want to clear all numbers from all displays. To clear all numbers, send a
page to P
ager 9999 with the message “99_98.”
o
Reset Factory Defaults
To change the display settings back to factory defaults send a page to P
ager 9999 with the message “99_99.”
o
Using the Display with Alternate Transmitters
The Visual-Pager® Display has been designed to work optimally with the MultiPage Transmitter. However, in
rare cases you may want to use the display with a transmitter other than the MultiPage. If so, you can control
the display's basic functions by sending pages to the d
isplay’s address with beep types and messages to
control the function.
Beep Type
“4” enters the number contained in the message into the display.
Beep Type
“3” removes the number contained in the message from the display.
Example: to add "123" to display ID 1500, do the following. Send a page to Pager 1500 with beep type 4,
message 123.