Microframe Corporation MultiPage B3011 Installation And Specification Manual Download Page 6

 

 

 

Microframe Corporation 

 

 

 

 

 

 

 

6

 

604 South 12

th

 Street 

Broken Arrow, OK  74012 
800-635-3811 
www.microframecorp.com 

 

 

 

 

 

 

Series 3500 

Installation 

The MultiPage Transmitter is designed to set on a flat surface or 
wall  mounted.    It  includes  a  removable  mounting  wedge.    To 
use the transmitter,  simply  plug  the  12-volt  DC  power  adapter 
into  the  back  of  the  transmitter  and  then  plug  the  adapter  into 
the wall.  The transmitter is now ready to use. 
 

Operation 

The  MultiPage  Transmitter  has  two  primary  operations.    It  can 
be  used  to  send  numbers  to  both  pager  and  Visual-Pager® 
displays. 
 
Sending Numbers to Visual-Pager® Displays 

 

To send a number to a display, simply type the number that 
you want to display, i.e. “1234” and then press [ENTER].   

 

To delete a number from the display, press [CANCEL] then 
type the number, i.e. “1234” then press [ENTER]. 

Paging Slimline Pagers 

 

To send a page to a vibrating pager (i.e. pager #

4), type the pager number “4” then press [SEND].  

 

You  will  then  be  prompted  for  the  Beep  Type.    Slimline  pagers  accept  any  beep  type  -  press  [ENTER]  to 
accept the default. 

 

Press [SEND].  If re-page is "ON," you will see the pager number re-paging on the bottom line.  To stop the 
re-page, press [CANCEL], type the number of the pager (e.g

. “4”) and then press [SEND]. 

 

Programmable Configurations 

The MultiPage Transmitter has eight programmable options.  To access these options press [SETUP] on the 
keypad, then press the 

“*” or “#” keys to move through the list of options.  When you come to an option you would 

like to change, press [ENTER].  Depending on the option, you can either press the 

“*” and “#” keys to change the 

value of the option, or you can type in the desired value.  To return to the main options menu press [ENTER].  
Once options are set, press [SEND] to save changes or [CANCEL] to discard changes.  Each of the eight options 
are described in detail below. 
 
OPTION 1 

– Transmitter Rollover Time 

The “Rollover” Time is the amount of time that each number in the transmitter memory shows on the LCD screen 
before rotating to the next number.  For example, with the transmitter Rollover Time set to three seconds, and the 
t

ransmitter with “123” and “456” in its memory, the transmitter will show “123” for three seconds and then show 

“456” for three seconds and then back to “123.”  To change the transmitter Rollover Time, simply use the “*“ and 
“#” keys to select a time from 1 to 16 seconds.  When the desired time is reached press [ENTER]. 

NOTE: The Transmitter Roll-Over Time is completely independent of the Display Roll-Over Time. 
NOTE: For 

“Hymn Mode”, set rollover time to 0.  See below for details. 

 
OPTION 2 

– Auto Delete Time

 

The Auto Delete Time is the time that a number remains on the transmitter before it is automatically deleted.  This 
time can be set using the  “*“ and “#” keys to select the desired value from 1 to 25 minutes.  Once the desired 
value is reached, press [ENTER] to return to the main menu. 

NOTE: The Visual-Pager® Display has an independent Auto Delete Time which is set following the instructions in 
the Visual-Pager® Display Section. 

The factory default for the display Auto Delete time is 45 minutes.  The reason for having an auto delete time in 
both  the  display  and  the  transmitter  is  best  understood  by  the  following  example:  At  the  end  of  the  day,  a  user 
may unplug the transmitter to turn it off.  If there are numbers being shown on the display, they will remain on the 
display until the display's auto delete removes them. 

 

 

MultiPage Transmitter 

 

 

 

Summary of Contents for MultiPage B3011

Page 1: ...7013 Manual No B3011 7013 Updated 11 2019 Rev 1 4 Microframe Corporation 604 South 12th Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 www microframecorp com support microframecorp com ...

Page 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Page 3: ...cificationGuide Table of Contents MultiPage System Overview and Features 4 MultiPage System Instructional Diagram 5 MultiPage Transmitter Features and Operation 6 Visual Pager Display Detailed Operation 8 Slimline 2 Pager Operation 10 Appendix A Changing the transmitter type 12 Model 3500 Specifications 13 Multipage Transmitter Specifications 14 ...

Page 4: ... Visual Pager Display The Wireless UHF Visual Pager Display has been designed to receive signals from the MultiPage Transmitter The display is available in a 2 3 4 or 6 digit model each of which has 5 5 tall red LED numbers Numbers sent to the display will be saved and shown on both the transmitter and the display until manually deleted or auto deleted depending upon user preference To enter a num...

Page 5: ...Microframe Corporation 5 604 South 12th Street Broken Arrow OK 74012 800 635 3811 www microframecorp com Series 3500 ...

Page 6: ...n type in the desired value To return to the main options menu press ENTER Once options are set press SEND to save changes or CANCEL to discard changes Each of the eight options are described in detail below OPTION 1 Transmitter Rollover Time The Rollover Time is the amount of time that each number in the transmitter memory shows on the LCD screen before rotating to the next number For example wit...

Page 7: ... recommended that users do not change this setting If you change this number the display and pager settings will have to be changed accordingly NOTE Slimline Pager Baud Rate can be re programmed at the base station OPTION 7 Out of Range This feature works with Slimline pagers When the out of range option is activated the transmitter will periodically send a page telling everyone that they still ar...

Page 8: ...eady to communicate with a MultiPage Transmitter Base ID 0500000 Baud Rate 1200 The display will intelligently communicate with other settings by doing the following Press the button on the back of the display one time The display will show vertical bars Next page Pager number 1 with a beep type of 2 and message 7337 The display should change to horizontal bars to signify that it has learned the t...

Page 9: ... is sent to the display The duration of the triac output can be controlled by changing this option To change this option send a page to 9999 with the message 03_XX where XX is a number from 00 to 99 representing the number of 0 1 second intervals that you want the output to be on i e 99 9 9 seconds Sending a 00 will cause the triac circuit to be disabled o Clear All Numbers Command There are occas...

Page 10: ...n right Changing the Alert Mode Pagers may be programmed to respond to a page by a combination of vibrating flashing and beeping By default the pagers are programmed to flash and vibrate for 2 minutes See below to set a new alert mode Out of Range These pagers can be programmed to alert continuously once they get out of range of the transmitter To use this feature first activate the option on the ...

Page 11: ... Reserved When you have selected the option you want press PROG Setting Starting Pager Number You can change the starting pager number for this base station For instance starting with pager 31 for a secondary base station Put the base station in program mode and select the STNO option Press PROG Use the up down arrows to set your desired starting number Hold down the PROG button to save about 3 se...

Page 12: ...tters are now supported by the same hardware platform When you order a B3011 or B3611 it should come pre programmed to the correct type To change the transmitter type Unplug power While pressing 0 and buttons plug in power At the password prompt type 0320 Enter Select 1 3500 or 2 3600 Press Enter to save Appendix A Changing the Transmitter Type ...

Page 13: ...wer Requirements 2 9 watts 3 5 watts 4 6 watts 6 8 watts Weight 2 5 lbs 3 2 lbs 3 9 lbs 5 25 lbs Width A Dimension Inches 9 8 13 2 16 8 24 Width A Dimension Centimeters 24 9 cm 33 5 cm 42 7 cm 61 4 cm Features The Visual Pager displays are designed to work best with the Microframe MultiPage System The displays have two modes 1 As a Visual Pager the display will store and rotate up to 20 numbers at...

Page 14: ...ea Typically 1 2 miles indoors Max 2 miles Mounting Desk or Wall Mount Dimensions 9 5 x 6 x 2 5 Excludes antenna Max Numbers Shown on Display 20 Max Pagers in Re Page Queue 30 Features This transmitter is designed to work out of the box with Multipage displays and Slimline pagers Operation Mode 1 Using the MultiPage Transmitter simply type in a number and press ENTER to send that number to the dis...

Reviews: