OPTION 3
– Re-Page Time for Pagers
This is the time between re-pages for pagers. For example, if the re-page time is set to one minute, then the
pager will be re-paged every mi
nute. Using the “*” and “#” keys, you may choose between 0 and 25 minutes for
the re-page time. A re-page time of 0 disables the re-paging feature. When you have selected your desired re-
page time, press [ENTER] to return to the main menu.
OPTION 4
– Set Display ID Address
This option is used to tell the transmitter the address of the display. The factory default is 1500. If you change
this address, you will also have to set up the display to respond to your new address (see Display Options.)
OPTION 5
– Base ID
The Base ID is the digital identification in which all components of a system run. The factory default for this
number is 0500000. This number may be changed to avoid “cross talk” with other nearby systems. It is
recommended that users do not change this setting. If you change this ID number, then the display and pager
settings will have to be changed accordingly.
NOTE: Slimline Pager Base ID can be re-programmed at the base station.
OPTION 6
– Baud Rate
This is the rate at which the digital communications takes place in your system. It is recommended that users do
not change this setting. If you change this number, the display and pager settings will have to be changed
accordingly.
NOTE: Slimline Pager Baud Rate can be re-programmed at the base station.
OPTION 7
– Out of Range
This feature works with Slimline pagers. When the out-of-range option is activated, the transmitter will periodically
send a page telling everyone that they still are in range. If the pager also has its out-of-range feature activated, it
will sound an alert within 1
minute of leaving the transmitter’s coverage area.
OPTION 8
– Behavior
The behavior option exists to accommodate those users who are more familiar with older DataPage Lite interface
and do not need the display or re-paging capabilities of the MultiPage. The behavior setting can be toggled
between “MultiPage” and “DataPage Lite." In DataPage Lite mode, the re-page feature is disabled and the
transmitter will simply wait for a pager number and then page a pager. The screen and button behavior will revert
to the DataPage Lite operation.
HYMN MODE
Overview: Hymn Mode allows the operator to pre-load a list of numbers. Uses: Hymn lists, etc.
Initial Setup:
•
To activate
“Hymn Mode”, set the rollover time option to 0.
•
We recommend setting the rollover time on the display to 0 as well.
Usage:
•
Enter each number in the order desired, pressing [Enter] after each one. The first number will show on
the transmitter, but the number won
’t show on the display yet.
•
Press [Enter] to send the number currently on the transmitter screen to the display.
•
Press
“#” to show the next number in the hymn list.