6.
In the
EDDYSTONE_URL_APP
, the detailed beacon information screen shows a Configure button. Click the
Configure
button. It requests that the user puts the beacon into Configuration mode. The SW0 hardware
button present on the SAM L21 Xplained Pro board has to be long pressed (around 3 seconds) to enter into
Configuration mode.
7.
Connect to the beacon in Configuration mode as shown in
. Once connected, the configurable
beacon parameters are listed out as shown in
Figure 5-70. Connecting to Beacon in Configuration Mode
Figure 5-71. Beacon Configuration Screen
8.
Update the URL, Tx Power mode, beacon period, etc. and then save. Now, disconnect from the beacon and
enter the ranging screen. Once disconnected, the beacon device (ATBTLC1000-MR/ZR) enters into Beacon
mode and start sending Eddystone URL frames with the updated values. The ranging console log screen
shows the beacon with new URL value.
ATBTLC1000
Application Demo
©
2019 Microchip Technology Inc.
User Guide