43
SPECIFICATIONS OF INVERTERS
SPECIFICATIONS OF INVERTERS
The Specifications apply when the Inverter Setting is set for AC Output = Normal Section10:7
14.1 5kW48 V Inverter Specifications
Model
5kW48V
Capacity Watt
5000
DC Input
Nominal Voltage
48 VDC
Acceptable Voltage Range
40-60 VDC
Maxi Input Amps
125 A
Standby Power
60 W
AC
Output
Voltage
230 VAC
Amps
22 A
Voltage Regulation
< 3 % RMS for entire battery voltage
range
Frequency
50Hz
Frequency Regulation
± 0.1Hz
Power Factor
1
Wave Form
Pure Sine Wave
Efficiency
90%
Hardware Protection
Circuit Breaker
Overload Protection
Programmable Overload levels and Auto
Retry
Charger
Float Voltage
Refer to Section 10.7
Boost Voltage
Refer to Section 10.6
Boost Time
Selectable 1min,30min, 1, 2, 3 hours
Maximum Current
50 A
Generator Mode
Depending on the generator power
available.