34
SETUP MENU SETTINGS
ENTER
Setup Menu ?
AC RUN TO
XX.XV
TRANSFER SWITCH
X
LOAD TRANSFER
X
AC OUTPUT
X
LOAD MONITOR
X
SETUP MENU
Exit And Save
SETUP MENU
Restore Factory
SETUP MENU
Exit, Do Not Save
SAVING DATA
PLEASE WAIT
PLEASE
WAIT
SELECT MODE
Solar Control
DC RUN TO
XX.XV
OR
PLEASE NOTE:
When Solar Control
Mode is selected,
Set the charge level
to “OFF” in the
battery setup menu.
OR
SETUP MENU SETTINGS
11.1 Setup Menu - Quick Reference Guide
Menu
Sub-Menu
Settings
3ms No
Soft Start
5ms No
Soft Start
8ms -
Soft Start
(Def)
GEN -
Soft Start
GEN -
Slow Ramp
High - No Reset
(Default)
Med - No Reset
High - 3x Reset
Med - 3x Reset
Low Emergency
Normal
(Default)
200%
No Delay
30 Sec Delay
(Default)
5 min Delay
SELECT MODE
UPS
From the Battery Setup
menu select the battery type
first
Lead Acid Battery Run to
Voltage
Lithium Battery Run To
Voltage
Lead Acid AC Run To
Voltage
Lithium AC run To Voltage
SELECT MODE
Load Shedding