Page 17
Technical Data
thermoMETER CTVideo
2.5.3
CTVM-3 Models
Model
CTVM-3L
CTVM-3H
CTVM-3H1
CTVM-3H2
CTVM-3H3
Temperature range (scalable)
50 ... 400 °C
1
100 ... 600 °C
1
150 ... 1000 °C
200 ... 1500 °C
250 ... 1800 °C
Spectral range
2.3 μm
2.3 μm
2.3 μm
2.3 μm
2.3 μm
Optical resolution
60:1
100:1
300:1
300:1
300:1
System accuracy
2 3
±(0.3 % of r2 °C)
4
Repeatability
2
±(0.1 % of r1 °C)
4
Temperature resolution
0.1 °C
4
Exposure time (90 % signal)
1 ms
5
Emissivity / Gain
0,100 … 1,100 (adjustable via programming keys or software)
Transmissivity
0,100 … 1,100 (adjustable via programming keys or software)
Signal processing
Average, peak hold, valley hold (adjustable via programming keys or software)
1) TObject > THead +25 °C
2) At operating temperature 23 ± 5 °C
3) Accuracy for thermocouple output: ± 2.5 °C or ± 1 %
4)
e
= 1/ Response time 1 s
5) With dynamic adaptation at low signal levels