Page 4
scanCONTROL 3000/BL / 3002/BL
Trigger, Encoder, Mode Switching
The switching inputs of the multifunction port can either be used for incoder input,
trigger input or for load previously stored user modes.
The signal levels are switchable for all switching inputs between LLL (TTL logic) and
HLL (HTL logic):
- LLL level: Low 0 V … 0.8 V, high 2.4 V … 5 V, internal pull-up/down switchable resis-
tor 10 kΩ
- HLL level: Low 0 V … 3 V, high 11 V … 24 V (permitted to 30 V), internal pull-up/
down switchable resistor 10 kΩ
-
Pulse duration: ≥ 5 µs
External Laser Switch-off, Optional
Externally switching off the laser is implemented as a hardware solution and is a top
priority. The laser can also be switched off by software.
This function is offered by sensors with the /SI option.
Use a serial key switch in the control circuit to switch of the laser.
With standard sensors, connecting the supply voltage activities the laser light source in
the sensor.
Wiring details are available in the operating instructions, Chap. 5.2.6.
Ethernet Connection, Standard Connection to PC
RJ45 connector
8-pin. screw connector (sensor side)
Pin no. Color of stranded hook-
up wire SCR3000A-x
Pin no. 10BaseT,
100BaseTX
1000BaseT
1
White (orange)
5
Tx+
D1+
2
Orange
6
Tx-
D1-
3
White (green)
8
Rx+
D2+
4
Blue
1
D3+
5
White (blue)
2
D3-
6
Green
7
Rx-
D2-
7
White (brown)
3
D4+
8
Brown
4
D4-
1
View on pin side
of male cable
connector
2
3
4
5
6
7
8
1
View on solder side (ca-
ble) of screw connector
(A-coded)