background image

Page 4

scanCONTROL 3000/BL / 3002/BL

Trigger, Encoder, Mode Switching

The switching inputs of the multifunction port can either be used for incoder input, 
trigger input or for load previously stored user modes. 
The signal levels are switchable for all switching inputs between LLL (TTL logic) and 
HLL (HTL logic):

 - LLL level: Low 0 V … 0.8 V, high 2.4 V … 5 V, internal pull-up/down switchable resis-

tor 10 kΩ

 - HLL level: Low 0 V … 3 V, high 11 V … 24 V (permitted to 30 V), internal pull-up/

down switchable resistor 10 kΩ

 -

Pulse duration: ≥ 5 µs

External Laser Switch-off, Optional

Externally switching off the laser is implemented as a hardware solution and is a top 
priority. The laser can also be switched off by software. 

This function is offered by sensors with the /SI option.

  Use a serial key switch in the control circuit to switch of the laser.

With standard sensors, connecting the supply voltage activities the laser light source in 
the sensor.

Wiring details are available in the operating instructions, Chap. 5.2.6.

Ethernet Connection, Standard Connection to PC

RJ45 connector

8-pin. screw connector (sensor side)

Pin no. Color of stranded hook-

up wire SCR3000A-x

Pin no. 10BaseT,  

100BaseTX

1000BaseT

1

White (orange)

5

Tx+

D1+

2

Orange

6

Tx-

D1-

3

White (green)

8

Rx+

D2+

4

Blue

1

D3+

5

White (blue)

2

D3-

6

Green

7

Rx-

D2-

7

White (brown)

3

D4+

8

Brown

4

D4-

1

View on pin side 
of male cable 
connector

2

3

4

5

6

7

8

1

View on solder side (ca-
ble) of screw connector 
(A-coded)

Summary of Contents for scanCONTROL 3000/BL

Page 1: ...ials detergents cooling emulsions Damage to or destruction of the sensor Read the detailed operating instructions before operating the sensor These instructions are available online at www micro epsilon com 2 Notes on CE Marking The following apply to the scanCONTROL 30xx BL EU Directive 2014 30 EU EU Directive 2011 65 EU The sensor is designed for use in industrial applications The sensor fulfill...

Page 2: ...or immediately turn away if the laser beam hits the eye Irritation or injury of the eyes possible Laser Class 2M The sensors fall within laser class 2M IIM The laser is operated on a pulsed mode the maximum optical power is 10 mW Attach the following warning labels to the cover front and rear side of the sensor housing LASER RADIATION DO NOT STARE INTO BEAM OR EXPOSE USERS OF TELESCOPE OPTICS CLAS...

Page 3: ... Pink Switching input In4 GND In 7 Black Ground connection In Shield Housing Black Not electrically connected to GND 2 3 4 5 6 7 8 9 1 10 11 12 GND Galvanically isolated from In1 In2 In3 In4 RS422 laser on off Laser on off Input galvanically isolated from GND In1 In2 In3 In4 RS422 In1 In2 In3 In4 RS422 Input galvanically isolated from GND and laser on off 12 pin screw connector view on solder side...

Page 4: ...ware solution and is a top priority The laser can also be switched off by software This function is offered by sensors with the SI option Use a serial key switch in the control circuit to switch of the laser With standard sensors connecting the supply voltage activities the laser light source in the sensor Wiring details are available in the operating instructions Chap 5 2 6 Ethernet Connection St...

Page 5: ...vailable online at https www micro epsilon de download software sensorTOOL exe LED Displays LED Laser LED Data LED Error Yellow Laser an Green Measure ment is active Red flashes Error code see operating instructions Chap 11 Green flashes Data transmission is active The LED Data flashes green long during active transmission and short for controller accesses 6 System Requirements scanCONTROL Configu...

Page 6: ...pply Close unused connection plugs with the included protec tive caps Turn on the power supply 24 VDC Please wait until the scanCONTROL measuring system is recognized by the PC This may take a few seconds Now you can operate the scanCONTROL measuring system with the scanCON TROL software packages i Operating a scanCONTROL sensor via Ethernet may require the IP settings of the PC sensor or the fire...

Page 7: ...tion about the measurement 9 How to Access Profile Data Profile data of scanCONTROL can be accessed via GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast application integration C C C and others Please refer to the respective SDK documentation for further information on accessing the profile data 10 Unpacking Included in Delivery 1 scanCONTROL 30xx BL sensor with integ...

Page 8: ...s about the individual programs in the respective operating instruc tions or in the operating instructions of this sensor Chap 6 2 You will find the operating instructions online at www micro epsilon com www micro epsilon com MICRO EPSILON Messtechnik GmbH Co KG Koenigbacher Str 15 94496 Ortenburg Germany Tel 49 0 85 42 1 68 0 Your local contact www micro epsilon com contact worldwide X9771399 04 ...

Reviews: