Page 5
scanCONTROL 3000/BL / 3002/BL
- The sensor supports an automatic, sensor-specific IP address in the link-local net
(169.254.x.x). No collision detection is implemented. This is also the default setting.
- The sensor supports DHCP. This setting is activated by default and has priority over
search the link-local net.
- The sensor scanCONTROL 30xx/BL supports Power over Ethernet.
If the sensor is connected to a POE-capable network adapter/
switch and you also use the power supply of the multifunction
port, these two power supplies must be galvanically islolated.
> Damage to the sensor and/or Ethernet card!
- A fixed IP address can be assigned.
Use the
sensorTOOL
program to make specify the sensor settings described
above.
The program is available online at
https://www.micro-epsilon.de/download/software/
LED Displays
LED
Laser
LED
Data
LED
Error
Yellow: Laser an Green: Measure-
ment is active
Red, flashes: Error code,
see operating instructions
Chap. 11.
Green, flashes:
Data transmission
is active
The LED
Data
flashes green, long during active transmission
and short for controller accesses.
6.
System Requirements
scanCONTROL Configuration Tools
The following minimum system requirements are necessary:
- Windows 7, Windows 8 or 8.1, Windows 10 (each 32 bit and 64 bit)
- 1-GHz or faster (32 bit and 64 bit) processor / 1 GB RAM (recommended 4 - 8 GB)
- Screen resolution: 1024 x 768 (recommended 1920 x 1080)
scanCONTROL 3D-View
The following minimum system requirements are necessary:
- Windows 8 or 8.1, Windows 10 (each 64 bit)
- 1-GHz or faster (64 bit) processor
- 1 GB RAM (recommended 16 GB)
- Screen resolution: 1024 x 768 (recommended 1920 x 1080)
- Graphics card / GPU with OpenGL 3.1 or higher