Page 24
optoCONTROL EDU190
Limit values (5)
When activating the
Active
checkbox, different limit value modes can be selected via a dropdown menu.
Entry of 2 limit values and optical display when limit values are exceeded or not reached.
No checkmark in the
Active
checkbox means inactive limit value outputs. The measured value is not high-
lighted in color.
Low limit - OK
- High limit
1
GOOD window
OK
Measured value within the specified upper and lower limit is highlighted in
green.
NOK
Outside of these limits (this window), the measured value is highlighted in
red.
Warn.limit -
Limit
1
Switches when the warning value
WV
is exceeded, measured value is highlighted in
orange.
When the value is even further exceeded, the measured value is highlighted in red
when the limit value
LV
is exceeded.
>Limit
1
Switches when the stated upper limit value is exceeded.
Black measurement value is highlighted in red.
<Limit
1
Switches when the stated lower limit value is not reached.
Black measurement value is highlighted in red.
1) OK = okay
NOK = not okay
High limit = upper limit value
Low limit = lower limit value