Delivery

boreCONTROL

Delivery

3. 

Supplied Items

3.1 

1 Sensor controller IFC24x1
1 BCR2410 consisting of BCM2410 and controller BCC2410
1 Sensor lance BCS241x-x with fitting calibration ring 
1 Optical fiber (sensor cable) S2410-x
1 Data cable SC2410-03
1 LAN cable
1 Synchronizatio

n cable SC2410-0.5

1 Serial cable RS232
1 CD with demo software and boreCONTROL-SDK
1 Disassembly aid
Optional Accessories, separate packed:

1 Power supply PS2020

1 boreSYSTEM

  Remove the parts of the system carefully from the packaging and transport them in 

such a way that they are not damaged.

  Check for completeness and shipping damages immediately after unpacking. In 

case of damage or missing parts, please contact the manufacturer or supplier.

Storage

3.2 

Storage temperature: 0 °C up to +75 °C
Relative humidity: 0 - 95 % (non-condensing)

Mounting

4. 

The sensors of the series BCS241x-x are optical sensors, which are used to measure in 
μm-range. 

i

  Handle optical sensors with care during mounting and operation.

Rotation Unit BCM2410

4.1 

ø 3.3 (.13)

ø 8.0 (.31)

ø45 

(1.77)

50/80 (1.97/3.15)

162 (6.38)

Mounting area

  Mount the rotation unit with a mounting 

adapter, see 

Fig. 3

This type of sensor mounting offers maxi-
mum reliability because the rotation unit is 
clamped around its cylindrical housing. It is 
absolutely necessary in difficult installation 
environments, e.g. on machines, produc-
tion plants etc.

Dimensional drawing rotation unit with sensor lance, dimensions in mm (inches)

Fig. 2 

CAUTION

Danger by detecting and 
winding the hair, the clo-
thes. Wear a hair net and 
tight clothing with rotary 
rotation unit.

Legend:

mm

(inches)

Summary of Contents for boreCONTROL

Page 1: ...Measuring system for internal wall inspection in bore holes Instruction manual boreCONTROL...

Page 2: ...O EPSILON MESSTECHNIK GmbH Co KG K nigbacher Stra e 15 D 94496 Ortenburg Tel 49 8542 168 0 Fax 49 8542 168 90 email info micro epsilon com www micro epsilon com Certified according to DIN EN ISO 9001...

Page 3: ...n Unit BCM2410 8 4 2 Controller BCC2410 9 4 3 IFC24x1 10 4 4 Electrical Connections BCC2410 10 4 4 1 Power Supply 10 4 4 2 Rotation Unit BCM2410 11 4 4 3 IFC 24x1 11 4 4 4 RS232 11 4 5 Electrical Conn...

Page 4: ...boreCONTROL...

Page 5: ...ry Damage to or destruction of the controller Avoid shock and vibration to the sensor and controllers Damage to or destruction of the sensor and controllers Avoid exposure to aggressive materials wash...

Page 6: ...158 F Humidity 5 95 non condensing Ambient pressure atmospheric pressure EMC According to EN 61000 6 3 2007 EN 61000 6 2 2005 Functional Principle Technical Data 2 Short Description 2 1 The rotating...

Page 7: ...sity max Intensity min Intensity ok Out of range Midrange In range Power On External light source Status In Ethernet External light source Sensor RS422 Encoder Dark reference STATUS PS2020 230 VAC PE...

Page 8: ...e contact the manufacturer or supplier Storage 3 2 Storage temperature 0 C up to 75 C Relative humidity 0 95 non condensing Mounting 4 The sensors of the series BCS241x x are optical sensors which are...

Page 9: ...rawing mounting adapter dimensions in mm inches not to scale Controller BCC2410 4 2 Keep the connectors free in mounted position Mount the controller on a DIN rail type TS35 R5 84 3 31 76 15 3 00 83 7...

Page 10: ...r Supply 4 4 1 The plug in terminal strip is designed for a conductor cross section of 0 25 mm to 1 0 mm The terminal strip is mounted on the controller with two screws and can be re moved for wiring...

Page 11: ...ensity ok Out of range Midrange In range Power On External light source Status In Ethernet External light source Sensor RS422 Encoder Dark reference STATUS IFC Sensor controller connected to the boreC...

Page 12: ...ernet External light source Sensor RS422 Encoder Dark reference STATUS PS2020 230 VAC PE N L Power supply of the boreCONTROL with a PS2020 Fig 9 Ethernet 4 5 2 Connect the controller connector Etherne...

Page 13: ...ror 1 GND Shield Error 2 GND HLL 24 VDC GND Shield U out GND U Shield I out GND I Power Digital I O RS422 Encoder Analog Out confocalDT Intensity max Intensity min Intensity ok Out of range Midrange I...

Page 14: ...from the packing Move the sensor into the rotation unit Turn the lock ring 90 degrees to the left Remove the disassembly aid in hori zontal direction Rotate the sensor until the marks on the sensor an...

Page 15: ...dismounting is described Slide the disassembly aid in hori zontal direction on the sensor Lock ring Sensor confocal Disassembly aid Turn the lock ring 90 degrees to the right Now the sensor is locked...

Page 16: ...g rate The dark signal should be acquired at all sampling rates in order to be able to subtract it while the controller is measuring A dark signal acquisition is performed during adjust ment by the ma...

Page 17: ...damages MICRO EPSILON always strives to supply the customers with the finest and most advanced equipment Development and refinement is therefore per formed continuously and the right to design changes...

Page 18: ...EMC requirements Part 1 General requirements We also declare that the special technical documentation for this partly completed ma chine has been created in accordance with Annex VII part B and commi...

Page 19: ......

Page 20: ...MICRO EPSILON MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon de X9751231 B02 X9751231 B021012HDR...

Reviews: