background image

EDM-MD Series 
Installation Manual

 

 

 

 

 

Page 16

 

 

 

 

6. Setting  

6.1 Basic Setting Code (Set the slide switch to PROGRAM) 

Code 

Function 

Volume 

Factory 

setting 

Remarks 

LED1 

LED2 

Hold Open Time 

1

1-9sec, A:10sec, B:20sec, C:30sec, D:40sec, E:50sec F:60sec. 

Open High 

Speed 

0

Setting of open high speed 

Open Low Speed 

0

Setting of open low speed 

Open Brake 

Force 

0

Setting of open brake force 

Open Force 

0

Setting of open motor torque 

Close High 

Speed 

0

Setting of close high speed 

Close Low Speed 

0

Setting of close low speed 

Close Brake 

Force 

0

Setting of close brake force 

Close Force 

0

Setting of close motor torque 

Partial Open 

Width 

0

Partial open is available by HO signal. 

0:35%, 1:50%, 2:65%, 3:80% 

Open Delay (*) 

0~3 

  0 : No delay time after un-lock signal is confirmed. 

1/2/3 : Below delay time from SS is activated to door starts to 

open. 

< 1:0.1sec, 2:0.5sec, 3:1.0 sec.> 

 

When set 1/2/3/, door opens regardless of whether unlock 

signal. 

If E-Lock can output unlock signal, it must be set "0". 

(*) :  

 

 

 

 

This function is available when SW4-4 is set OFF 

 

When SW-4 is set ON, door starts to open upon SS without delay. 
 

 

 

 

Summary of Contents for EDM-MD Series

Page 1: ...stallation Manual Page 1 MICOM AUTODOOR Automatic Sliding Door Operator Model EDM MD Original Instructions EN16005 Compliant INSTALLATION MANUAL OSAKA JAPAN www micomautodoor com REVISED DATE JUNE 201...

Page 2: ...r supply whilst door s in motion Ensure sliding door travel area is clear before switching power switch ON Keep fingers clothing hair clear of belt and all moving parts Protective gloves should be wor...

Page 3: ...ing Doors 3 5 Smooth Operation 3 6 Power On 4 Teaching Learning Operation 4 1 Teaching Learning 5 Set Up Operation 5 1 Motor Gear Box 5 2 Control Box 6 Setting Table 6 1 Basic Setting Code 6 2 Hold Op...

Page 4: ...accessible LED visual display found on EDM MD Control box face Connections for sensor and other inputs are located as either an independent input terminal on the rail or by adding MICOM Sensor and Ba...

Page 5: ...ange of sensors such as BEA IXIO S Optex 0A Axis T 1 3 Delivery MICOM EDM MD Series can be supplied in several formats as follows Complete Operator consisting of Base Rail Cover Control Box Connection...

Page 6: ...vailable Closed Exit Auto Open Emergency Exit Option Door Profile Solutions Various Fixed and Moving profile designs available without glass Frameless Glass Brackets Fitting Brackets for 10mm and 12mm...

Page 7: ...y 2 Hanger Roller Bracket with Belt Bracket Link Assembly Double Leaf 3 Tooth Belt 4 Hanger Roller Bracket with Belt Bracket Link Assembly Single Leaf 5 EDM MD Control Box 6 Base Rail with Side Cover...

Page 8: ...n Option outside of EU 2 2 1 SMB No Description 1 SMB output to Control Box 2 Internal Sensor Input 3 External Sensor Input 4 LED Error Indicator 5 DIP Switch 6 E Lock Timer 7 Side Screen Sensor Input...

Page 9: ...witch 4 Position Key Note If SMB is not used please refer to section 10 1 for MICOM Function Selector 4 Position Symbol Description Closed Locked Exit Only Automatic Hold Open Exit In case Locked is s...

Page 10: ...n access at all times during works being carried out Positioning and Installing base rail Refer to below EDM MD Drawing to find correct measurement of base rail position Ensure hanger roller brackets...

Page 11: ...EDM MD Series Installation Manual Page 11 3 3 EDM MD Front View...

Page 12: ...orrectly installed Refer to wiring diagrams Sec 8 The power switch is located to the right of motor fixed to the underside of the base rail 4 Teaching Learning Operation CAUTION Ensure that the door t...

Page 13: ...learn it s stoke In case of a malfunction or in the event that the stored data is affected by electric noise during its operation the controller can be recovered by another RESET We recommend taking...

Page 14: ...T Set to RUN then teaching starts How to change setting UP SET ON OFF Change LED 1 value OFF ON LED 2 flash ON OFF Change LED 2 value OFF ON Value is fixed LED 1 2 lights are on Repeat this to change...

Page 15: ...ogramming mode Slide switch from RUN to PROG See setting table Sec 6 5 SW4 Note After changing setting of SW4 turn the main power OFF ON to save adjustment SW1 Opening direction SW2 RS function Ratche...

Page 16: ...A 5 Setting of close high speed 6 Close Low Speed 0 A 4 Setting of close low speed 7 Close Brake Force 0 A 5 Setting of close brake force 8 Close Force 0 A 3 Setting of close motor torque 9 Partial Op...

Page 17: ...in the threshold and not detected by safety devices the following obstruction detection function will ensure safe operation as follows 7 1 During closing travel On contact with object doors will reve...

Page 18: ...200 240V AC 0 7A Power Output 24V DC 300mA Manual door opening closing force during power failure 24 5 39 2N 2 5 4kgf 29 4 49 0N 3 5kgf Open Door Speed Adjustable 160 500mm s Close Door Speed Adjustab...

Page 19: ...ction Selectors are easy to install and operate Supplied in a fire retardant black plastic mount box with attractive cover design in white our function selectors can be fitted to walls or aluminium fr...

Page 20: ...EDM MD Series Installation Manual Page 20 10 2 Wiring Drawing MICOM Function Selector Switch 4 Position with Rotary Knob Available in 2 configurations 10 2 1 Rotary Function Selector 4 Position...

Page 21: ...EDM MD Series Installation Manual Page 21 10 2 2 Rotary Function Selector Switch 4 Positions with Push Button Exit...

Page 22: ...en Time 1 F Steps 1 1 Open High Speed 500mm s MAX 0 A Steps 7 2 Open Low Speed 0 A Steps 4 3 Open Brake Force 0 A Steps 5 4 Open Force 0 A Steps 5 5 Close High Speed 400mm s MAX 0 A Steps 5 6 Close Lo...

Page 23: ...on House Regent Centre Gosforth Newcastle Upon Tyne NE3 3PF U K Tel 0044 0191 2336323 Fax 0044 0191 2840222 E Mail info micomautodoor com Copyright 2011 MICOM Autodoor The contents of the document are...

Reviews: