EDM-MD Series
Installation Manual
Page 14
5.2 Control Box Assembly EDM MD
No.
1.
Power Input Plug in 200~240VAC
2. RUN/PRG switch
Slide switch to change from RUN mode to PROGRAM mode
3. TEST / UP & SET Buttons
TEST Button – Used to check the basic function of the operator when servicing or
installation. Activation signal for Test open cycle (RUN mode only)
UP & SET Button – Used when in PROGRAM mode only. (To entre Programming
mode: Slide switch from RUN to PROG.)
<How to RESET>
UP SET
ON ON : Hold both buttons to RESET. Set to “RUN”, then teaching starts.
<How to change setting>
UP SET
ON OFF : Change LED 1 value
OFF ON : LED 2 flash
ON OFF : Change LED 2 value
OFF ON : Value is fixed (LED 1/2 lights are on)
(Repeat this to change setting)
4. LED Display
LED Display is a visual display for the installer in order to correctly set up and operate
MICOM EDM MD Operator.
LED DISPLAY:
LED1 : Function / Application
LED2 : Parameter Value
Green LED : Power indicator
Red LED : Sensor indicator (SS or SB)
‘RUN’ Mode
When in ‘RUN’ mode, the operator will run as normal. LED display will show:
a.
Number of open cycles. (Memory is cleared by main-power off).
b.
Error indication
Error Code:
E0 : Door travel distance during teaching cycle is too short (less than 150mm).