Symptom
Potential cause
Remedy
The stapling device is not
being sufficiently lubricated.
Add special oil to the compressed air
connection in use.
Trigger several times.
Operating pressure is too
low.
Increase operating pressure (see page 21).
The piston with the driver
does not return to the initial
position after the driving
process.
Inform customer service.
The triggering process is not
completed.
Inform customer service.
The driver is bent.
Inform customer service.
A staples is jammed.
Remove jammed staples.
Otherwise, inform customer service.
If the fault cannot be corrected, contact your dealer or the manufacturer.
17.4
staples
Only the Original MEZGER staples ZH 16 may be used with the stapling device.
Type
Wire
Crown size
Leg length
ZH 16 25
2,2 mm
23 mm
25 mm
ZH 16 30
2,2 mm
23 mm
30 mm
ZH 16 38
2,2 mm
23 mm
38 mm