C
ompressed-air Stapling Plier
Z 23 P
Page:
21
Mod.:
01/2022
ET
Seite 21 von 34 31.01.22 P:\Technik\ZANGEN\Z 23 P\Bedienungsanleitung\Englisch\Manual Z 23 P Pneum en_01_2022.docx
13.6
Contact triggering
The device is set for contact triggering. For repeated triggering, you do not need to press the
trigger each time. Each trigger action drives one staple into the material.
The device must not be used in the following cases:
For applications that require the stapling device to be moved across scaffolding, stairs, ladders,
or ladder-like structures.
For closing crates or boxes.
For applying transport locks.
13.7
Set drive depth
You can set the drive depth of the staples into the carton material by adjusting the bottom
retaining clip and by controlling the operating pressure.
13.8
Controlling operating pressure
You can set the drive depth of the staples into the material by controlling the operating pressure.
At higher operating pressure, the staples are driven deeper, and at lower operating pressure
they are driven less deep.
When operating with a compressed air hose, you can only turn up the operating
pressure on the stapling device to a maximum of the output pressure of the
compressor.
13.8.1
Set drive depth with bottom retaining clip
You can set the drive depth of the staples
into the carton material by adjusting the
bottom retaining clip.
►
To reduce the drive depth, loosen the cap
screw (1) and adjust the bottom retaining
clip (2) downward.
To increase the drive depth, loosen the
cap screw (1) and adjust the bottom
retaining clip (2) upward.