C
ompressed-air Stapling Plier
Z 23 P
Page:
16
Mod.:
01/2022
ET
Seite 16 von 34 31.01.22 P:\Technik\ZANGEN\Z 23 P\Bedienungsanleitung\Englisch\Manual Z 23 P Pneum en_01_2022.docx
If no oiler is installed, the length of the air line to the stapling device must not exceed 10 m.
Otherwise, you must add three to five drops of special oil directly into the air inlet of the
stapling device every day prior to starting operation.
The compressed air system must be able to maintain operating pressure even when the
desired amount of air is being used.
The inner diameter of the air line must be at least 8 mm.
The connector for the stapling device must be equipped with a quick-connect coupling with
nominal diameter of 7.2 and at least 6.5 mm inner diameter.
CAUTION
Operation with compressed air systems that do not meet the above conditions
can cause damage to the stapling device.
Operate the stapling device only with a suitable compressed air system.
Use the stapling device only if it is flawless condition.
Check the condition of the stapling device.
Remove the plug from the connector for the air hose.
Check the connector for the air hose for foreign objects and dirt and clean it if needed.
Set the operating pressure at the pressure regulator on the compressor to 5
–
8 bar.
WARNING
Accidentally triggering when connecting to the compressed air supply can cause
severe or fatal injury.
Do not point the stapling device at people or animals.
Empty the magazine before connecting.
CAUTION
Damaged air lines can burst and cause injury.
Check the compressed air system and the stapling device for damage before connecting.
Connect the stapling device only to a functioning compressed air system.
ATTENTION
Damaged hoses can burst and cause property damage due to escaping compressed air.
Check the compressed air system and the stapling device for damage before connecting.
Connect the stapling device only to a functioning compressed air system.
Set the operating pressure at the pressure regulator on the compressor to a maximum of 8 bar.
Check the connector for the pressure hose and the quick-connect on the pressure hose for
foreign objects and dirt and clean them if needed.