-   If the leakage test is satisfactory and no gas is escaping, open the cylinder valve by turning the knob to the 

left (counterclockwise) unless it has already been opened after the leakage check. 

-  Press the heater valve control button and turn it to ignition position (

 Pilot - approx. 90° to the left). Hold 

the control knob pressed for approx. 30 seconds (before the fitting with the hose is filled with the gas from 
the cylinder that is pushed out of the gas distribution by air); at the same time, press also the switch button 
of the piezo igniter (Igniter  - red) and hold them both pressed until the ignition burner flame is ignited. 
After the ignition burner flame is ignited, release the piezo igniter switch button. The pressed heater valve 
control knob may be released after approx. 15 sec after the flame is ignited (after the thermal fuse is heated-
up). 

-  After the ignition flame is ignited and the heater valve control knob is released, turn this knob slowly more 

counterclockwise to the maximum position (Hi  - approx. 45° to the left), which ignites the heater main 
burner to the maximum output. Wait in this position for approx. 5 min and then set the required heater 
output by turning the heater valve control knob to the selected position between the maximum (Hi) and the 
minimum (Lo). 

 

Note:  If the burner is not ignited, press and turn the heater valve control knob to closed position (

 Off) 

and release; wait for approx. 5 min and repeat the procedure.

 

 
Extinguishing the heater 
-  Turn the heater valve control knob to ignition position (

 Pilot), press the knob in this position, turn it to 

closed position (

 Off), and release. 

-  Close the fuel inlet from the LPG cylinder by turning the cylinder valve knob to the right up to stop. 
 
When turned off for a long time: 
-  Turn the heater valve control knob to ignition position (

 Pilot). 

-  Close the fuel inlet from the LPG cylinder by turning the cylinder valve knob to the right up to stop and let 

the remaining gas from the connecting hose combust. 

-  Press the heater valve control button, turn it to closed position (

 Off) and release. 

-

 

When turning off for a long time, always disconnect the heater from the gas cylinder (see Disconnecting 
the heater and changing the LPG cylinder). 

 
Disconnecting the heater and changing the LPG cylinder 
-  Extinguish the heater (see Extinguishing the heater - Procedure for turning off for a long time). 
-  Before disconnecting the gas cylinder, check whether the heater is extinguished and cooled completely and 

whether the cylinder valve is closed. 

-  Disconnect  the  LPG  cylinder  from  the  stove  and  check  the  cylinder  valve  for  leakage  and  damage.  If 

a defect is found, the LPG cylinder shall be supplied to the gas supplier for replacement. Mount a protective 
plug on the disconnected cylinder. 

-  If the heater is not to be connected to another LPG cylinder, place it so as to avoid its fouling or mechanical 

damage. 

-  Prior to connecting a new gas cylinder to the appliance check the condition of sealing. 
-  Change the gas cylinder in a sufficiently ventilated room, preferably in an outdoor environment, outside all 

sources of ignition (a candle, cigarettes, other appliances producing a flame, etc.) and out of reach of other 
persons. 

-  After the new cylinder is connected, make a leakage check (see Leakage check). 
 
Leakage check 
-  In  the  place of  installation a  complete leakage  test  of the appliance  must  be  carried  out  due to  possible 

damage during transport or excessive pressure. 

-  Carry  out a  leakage  test  after every  relocation  of  the appliance  or  change  of the  LPG  cylinder  or  if  the 

appliance has been put out of operation for a long time. 

-  Prepare a foam forming solution using one part of liquid detergent and one part of water. Apply the foam 

forming solution using an atomizer vessel, brush, or cloth. 

-  Carry out a check when the pressure cylinder is full sufficiently. 
-  Check whether the heater valve control knob is in closed position/OFF (

 Off) and is not pressed. 

-   Open the cylinder valve on the LPG cylinder by turning the knob to the left, apply a foam forming solution 

(e.g. soapy water) and check the hose and the areas around the connections for escaping gas. Escaping gas 
will  be  accompanied  by  the  formation  of  bubbles in the  area  of leakage. The  heater  valve  control  knob 

Summary of Contents for FH600

Page 1: ...Kategorie spot ebi e p ipojovac p etlak a druh paliva pro jednotliv zem jsou uvedeny v kapitole Technick data Pro eskou republiku plat e tento spot ebi se pou v pouze s LPG lahv pln nou sm s butanu p...

Page 2: ...ie Cat P ipojovac p etlak p Druh paliva Gas Jmenovit tepeln p kon Qn Spot eba M CZ SK BG I3B P 30 28 30 mbar G30 propan butan nebo jejich sm si 12 5 kW 870 g h Pr m r trysky zapalovac ho ho ku 0 18 mm...

Page 3: ...dal d ly odstra te ji i z nich N ad pot ebn k mont i sou st balen Kl roubov k Seznam d l spot ebi e Ozna en N zev d lu Po et ks Ozna en N zev d lu Po et ks A Reflektor 1 I Spojovac hadice v hadicov ch...

Page 4: ...BB Matice s p rubou M6 4 CC roub M5 x 12 3 HH roub 3 16 27 3 DD Podp ra reflektoru 3 II chytka 1 JJ roub M4 x 6 1 EE K dlat matice 3 KK et z 1 FF Podlo ka 8 6 Postup mont e 1 P ipevn te ke spodn desc...

Page 5: ...te epy s osazen m ve spodn desce do pr sek ve tvaru kl ov d rky v doln ch podp r ch Pot p ipevn te doln podp ry ke spodn desce pomoc 3 ks roub M5 x 12 CC D le ustavte spr vnou polohu doln ch podp r a...

Page 6: ...B a p ipevn te ho k horn m podp r m D pomoc 6 ks roub 3 16 HH Pro p ipojen pou ijte voln d ry ve spodn sti dr ku reflektoru Zkontrolujte zda sklen n trubice zcela zakr v st edov otvor v ovl dac m pane...

Page 7: ...k do ov ln ch otvor v horn ch podp r ch D Zajist te polohu ochrann ho krytu zp tnou mont 1 ks dr ku krytu GG a 1 ks roubu 3 16 HH T mto zp sobem postupn p ipevn te v echny 3 ks ochrann ch kryt P i mo...

Page 8: ...ku pomoc 1 ks roubu M4 x 6 JJ Usa te oba panty vyhnut zob ky na vnit n stran eln ho panelu do prost i en ch v stupk ve spodn desce N Zah kn te h ek na voln m konci et zu do ov ln ho otvoru v ovl dac m...

Page 9: ...entilu topidla mus b t v uzav en poloze Off P ipojenou LPG lahev postavte do ur en ho prostoru v topidle na spodn desku a jej polohu zajist te p skem L Zabra te zkroucen hadice a jej mu styku s hork m...

Page 10: ...kontrolujte t snost a neporu enost lahvov ho ventilu Zjist te li z vadu p edejte LPG lahev dodavateli plynu k v m n Odpojenou lahev opat ete ochranou z tkou Pokud topidlo nebudete p ipojovat na jinou...

Page 11: ...ry ho ku Men ne istoty je mo n odstranit stla en m vzduchem Proud n vzduchu nesm b t dn m zp sobem omezov no Udr ujte ovl dac prvky ho k a otvory k proud n vzduchu ist Po del ne innosti je nutn u plyn...

Page 12: ...P edat odborn mu servisu k oprav Plamen zapalovac ho ho ku zhas n Zne i t n kolem ho ku O istit zne ist n m sta Uvoln n spoje Dot hnout v echny spoje Vadn termopojistka P edat odborn mu servisu k v m...

Page 13: ...bi e V lo n m prostoru pro tlakovou lahev na LPG v topidle neskladujte benz n ani jin ho lav kapaliny nebo p ry Nevhodn instalace se zen nebo pravy mohou zp sobit poran n osob nebo hmotn kody Nenat re...

Page 14: ...rove je nutn zabr nit p padn mu nebezpe n mu hromad n nesp len ho paliva u spot ebi e Propan butan i jejich sm si jsou z fyzik ln ho hlediska t ne vzduch a v p pad samovoln ho niku v d sledku net sno...

Page 15: ...za v robky 24 m s c ode dne prodeje V robce Changzhou Hongmaoxinda Furnace Co Ltd No 22 Hexiang West Road Wujin Economic Development Zone 213149 Changzhou Jiangsu China Opravy a servis Z ru n i mimoz...

Page 16: ...a pod Kateg ria spotrebi a prip jac pretlak a druh paliva pre jednotliv krajiny s uveden v kapitole Technick daje Pre esk republiku plat e tento spotrebi sa pou va iba s LPG f a ou plnenou zmesou prop...

Page 17: ...a Cat Pripojovac pretlak p Druh paliva Gas Menovit tepeln pr kon Qn Spotreba M CZ SK BG I3B P 30 28 30 mbar G30 prop n but n alebo ich zmesi 12 5 kW 870 g h Priemer d zy zapa ovacieho hor ka 0 18 mm o...

Page 18: ...l ie diely odstr te ju aj z nich N radie potrebn na mont s as balenia K Skrutkova Zoznam dielov spotrebi a Ozna enie N zov dielu Po et ks Ozna enie N zov dielu Po et ks A Reflektor 1 I Spojovacia hadi...

Page 19: ...ica s pr rubou M6 4 CC Skrutka M5 x 12 3 HH Skrutka 3 16 27 3 DD Podpera reflektora 3 II chytka 1 JJ Skrutka M4 x 6 1 EE Kr dlov matica 3 KK Re az 1 FF Podlo ka 8 6 Postup mont e 1 Pripevnite k spodne...

Page 20: ...saden m v spodnej doske do priesekov v tvaru k ovej dierky v doln ch podper ch Potom pripevnite doln podpery k spodnej doske pomocou 3 ks skrutiek M5 x 12 CC alej nastavte spr vnu polohu doln ch podpi...

Page 21: ...B a pripevnite ho k horn m podper m D pomocou 6 ks skrutiek 3 16 HH Na pripojenie pou ite vo n diery v spodnej asti dr iaka reflektora Skontrolujte i sklenen trubica plne zakr va stredov otvor v ovl...

Page 22: ...ov lnych otvorov v horn ch podper ch D Zaistite polohu ochrann ho krytu sp tnou mont ou 1 ks dr iaka krytu GG a 1 ks skrutky 3 16 HH T mto sp sobom postupne pripevnite v etky 3 ks ochrann ch krytov Pr...

Page 23: ...ika pomocou 1 ks skrutky M4 x 6 JJ Usa te oba p nty vyhnut zob iky na vn tornej strane eln ho panela do prestrihnut ch v stupkov v spodnej doske N Zah kujte h ik na vo nom konci re aze do ov lneho ot...

Page 24: ...saden na vstupnom t ni armat ry ohrieva a a zaisten hadicovou sponou u od v robcu Ovl dac gomb k ventilu ohrieva a mus by v uzavretej polohe Off Pripojen LPG f a u postavte do ur en ho priestoru v ohr...

Page 25: ...ohrieva a a v mena LPG f a e Zhasnite ohrieva pozrite Zh anie ohrieva a postup pri dlhodobom vypnut Pred odpojen m f a e na plyn skontrolujte i je ohrieva zhasnut je plne vychladnut a i je uzatvoren...

Page 26: ...a smie vykon va iba vtedy ak je spotrebi vypnut plne vychladnut a odpojen od LPG f a e istenie ohrieva a vykon vajte vlhkou handri kou bez pou itia abraz vneho prostriedku Ne istite spotrebi hor av mi...

Page 27: ...i LPG f a u Ovl danie nie je zapnut Oto i ovl dac gomb k ventila ohrieva a do spr vnej polohy Upchat rozvod plynu Skontrolova priechodnos rozvodu plynu hadice tesnenie at Upchat d za Odovzda odborn mu...

Page 28: ...ch pl ch dvere okn a pod aby nedo lo p soben m tepla k ich po kodeniu Pri prev dzke je nutn ohrieva umiestni na vodorovn spevnen povrch a ma ho pod doh adom Dbajte na to aby ohrieva bol v suchom a ist...

Page 29: ...y alebo v pr pade po kodenia hadicu vyme te Hadicu vyme te v inom intervale ak to vy aduj odli n n rodn podmienky V mena hadice sa mus vykon va v predp san ch intervaloch Neprip jajte f a u na plyn pr...

Page 30: ...bl zkosti hor ka a pod sa nevz ahuj z ru n podmienky preto e ich nie je mo n pova ova za chybu v robku Niektor zmeny be n prev dzkov opotrebovanie sa m u na v robku prejavi u po nieko k ch m lo pou it...

Page 31: ...31 MEVA TEC s r o Roudnice n L HEXAGON UTZ21001 FH600 1950 mm 900 mm 570 mm 520 mm...

Page 32: ...R LPG LPG LPG Liquefied Petroleum Gas 10 mbar 1 kPa 1 NP01008 30 mbar 1 NP01022 0 6 m 2 IM905 1 1 NP01008 I3B P 30 Dest Cat p Gas Qn M CZ SK BG I3B P 30 28 30 mbar G30 12 5 kW 870 g 0 18 mm 0 18 1 80...

Page 33: ...33 LL MM A B C D E F G H I J K L M N 1 2 25 3 100 cm 100 cm A 100 cm 100 cm...

Page 34: ...34 A 1 I 1 B 1 C UTZ21003 1 J 1 D 3 E 3 K 3 F 1 L 1 G 2 H 1 M 1 N 1 AA M6 x 12 4 GG 3 BB M6 4 CC M5 x 12 3 HH 3 16 27 3 DD 3 II 1 JJ M4 x 6 1 EE 3 KK 1 FF 8 6...

Page 35: ...35 CC x 3 MM x 1 1 M N 4 M6 x 12 AA 4 M6 BB 2 J A 1 5 V K N J 3 M5 x 12 CC 3 3 16 HH J L 2 AA x 4 BB x 4 1 AA N M BB HH x 3 LL x 1 2 J K CC N HH L...

Page 36: ...36 3 D K 6 3 16 HH 4 C J B D 6 3 16 HH D K HH 3 MM x 1 HH x 6 MM x 1 HH x 6 4 B D HH C J...

Page 37: ...37 GG x 3 HH x 3 MM x 1 5 A B 3 DD 6 8 FF 3 EE 6 1 GG B 1 3 16 HH E D 1 GG 1 3 16 HH 2 3 16 HH B DD x 3 EE x 3 FF x 6 5 FF EE A FF DD B 6 E GG D HH...

Page 38: ...38 7 G K 12 3 16 HH 8 H II 1 M4 x 6 JJ N J JJ x 1 II x 1 HH x 12 MM x 1 7 HH G K MM x 1 KK x 1 8 H II JJ KK N...

Page 39: ...39 LPG H N LPG LPG LPG LPG Off L H N LPG C J AAA 1 5 V Off 1 2 3 4 2 5 1 2 3 4 10 kg a 5...

Page 40: ...40 Pilot 90 30 Igniter 15 Hi 45 5 Hi Lo Off 5 Pilot Off LPG Pilot LPG Off LPG LPG LPG LPG LPG Off...

Page 41: ...41 LPG LPG LPG LPG 2 3 LPG...

Page 42: ...42 LPG LPG 21 1979 2 LPG LPG LPG AAA 1 5 V LPG LPG LPG LPG...

Page 43: ...43 LPG LPG LPG LPG LPG HEXAGON UTZ21002 10 C 80 18 LPG...

Page 44: ...44 LPG LPG LPG 40 C LPG EN 16436 1 EN ISO 3821 LPG 0 6 m LPG 5 EN 16129 10...

Page 45: ...45 2 24 Changzhou Hongmaoxinda Furnace Co Ltd No 22 Hexiang West Road Wujin Economic Development Zone 213149 Changzhou Jiangsu China 1839 12 02 841 1050...

Page 46: ...tly ventilated rooms garden restaurants marketplaces gardens terraces and the like For the appliance category supply pressure and type of fuel for individual countries please refer to the Technical da...

Page 47: ...Country of destination Dest Category Cat Supply pressure p Type of gas Gas Nominal heat input Qn Consumption M CZ SK BG I3B P 30 28 30 mbar G30 propane butane or their mixtures 12 5 kW 870 g h Ignitio...

Page 48: ...e equipped with film remove the film also from them Tools required for installation included in the package Wrench Screwdriver List of parts of the appliance Marking Part Name Number pcs Marking Part...

Page 49: ...ut with flange M6 4 CC Bolt M5 x 12 3 HH Screw 3 16 27 3 DD Reflector support 3 II Handle 1 JJ Bolt M4 x 6 1 EE Wing nut 3 KK Chain 1 FF Washer 8 6 Installation Procedure 1 Connect the wheels M to the...

Page 50: ...epped pins in the lower plate into the cut holes keyhole shaped in the lower supports Then fasten the lower supports to the lower plate using 3 pcs M5 x 12 bolts CC After that set the lower supports a...

Page 51: ...and fasten it to the upper supports D using 6 pcs 3 16 screws HH To connect use the spare holes in the bottom part of the reflector holder Check whether the glass tube covers completely the central h...

Page 52: ...ports D Secure the position of the protective cover by reinstalling one cover holder GG and 1 pc 3 16 screw HH Fasten all the three protective covers one by one in this way During installation have al...

Page 53: ...pc M4 x 6 bolt JJ Place both hinges the beaks bend outwards on the inside of the front panel into the cut protrusions in the lower plate N Hook the hook at the free end of the chain into the oval hol...

Page 54: ...e heater fitting inlet mandrel on the right side of the control panel and tighten using the hose clamp Note One end of the connecting hose may be placed on the heater fitting inlet mandrel and secured...

Page 55: ...n turn it to closed position Off and release When turning off for a long time always disconnect the heater from the gas cylinder see Disconnecting the heater and changing the LPG cylinder Disconnectin...

Page 56: ...eater at rest for approx 2 3 min and then follow the instructions for igniting Cleaning and maintenance Keep the appliance in dry and clean conditions Perform the appliance maintenance at regular inte...

Page 57: ...ons service troubleshooting etc would be troublesome for you contact the authorized service center manufacturer importer MEVA TEC s r o tel 420 416 823 181 299 www mevatec cz Defect Possible causes Re...

Page 58: ...appliance the operator shall respect the general fire safety regulations In no case the appliance may be operated by children Protect the appliance against children during its use as well as storage...

Page 59: ...regulator and connecting hose shall either be placed away from walkways or placed in a way that they would not get damaged Use hoses complying with EN 16436 1 or EN ISO 3821 or other hoses designated...

Page 60: ...er is not liable for damage caused by improper handling or maintenance beyond the scope of the applicable installation and operating instructions The warranty terms and conditions shall not apply to a...

Reviews: