5. Monitoring, warning, error, repair
page 32
ELC PE22B-PE35B V1.0-05.19-GB
Subject to technical alterations
5.4.
Error
5.4.1.
Error messages
Effects of an error:
The lamp will be immediately shut down,
In case of an error the red Status-LED is blinking (s. Fig. 7),
For description of the errors and trouble shooting see chapter 5.4.2,
Bits in the
[Error Register]
will be set as soon as the correspondent error occurs and must be
reset for further lamp operation (see chapter 5.4.3).
PROFIBUS-input-data (ELC
→
Master)
Byte-
No.
0 1 2 3
4
5
6
7
8
9
10 11 12 13 14
15
Name
[ELC
Serial
Number]
[Software
Version]
[ELC
Nominal
Power]
[Error
Register]
[Warning
Register]
[Lamp
Status]
[Actual
Power]
[Actual
Voltage]
[Actual
Current]
[Reserved]
↓
Byte
6
Bit
15
14
13
12
11
10
9
8
Name
n/a
n/a
Lamp
Power
Low
Supply
ZVS
Earth
Leakage
Fault
Measure-
ment
Overcurrent
Byte
7
Bit
7
6
5
4
3
2
1
0
Name
Lamp
Voltage
High
Over-
voltage
Bus
Connection
Error
internal ELC
Temperature
High
n/a
Mains
Voltage
Low
DC-Link
Undervoltage