4. Operation of ELC
page 25
ELC PE22B-PE35B V1.0-05.19-GB
Subject to technical alterations
Further operation data of the continuous operation state may be read out from the registers
[Actual Power]
,
[Actual Voltage]
and
[Actual Current]
:
[Actual Power]
returns the actual power in Watts.
[Actual Voltage]
gives account of the actual lamp voltage in Volts.
[Actual Current]
contains the actual current in Ampère*10 with an accuracy of 100 mA (e.g.:
[Actual Current] = 12 means 1.2 A).
4.5.
Dimming operation
After having reached nominal operation the desired lamp power can be infinitely adjusted.
Enter the desired power in Watts in register
[Power Set Value]
.
A set value of less than 20% of the ELC-nominal-power will automatically be
increased by the ELC to 20% of the ELC nominal- power.
4.6.
Standby operation
During longer idle times the ELC can be switched to standby operation. The lamp is operated
at minimum power but can be brought up to nominal power within a few seconds.
Standby operation corresponds to 20% of the ELC nominal power. This can be attained by setting
the register
[Power Set Value]
at a value equal to or lower than 20% of ELC nominal power.
The warm-up time from standby operation to nominal operation depends on the lamp's
ambient conditions. If cooling is too intensive during dimming operation, the warm-up time is
prolonged.