3. Installation
page 22
ELC PE22B-PE35B V1.0-05.19-GB
Subject to technical alterations
3.5.5.
Temperature derating for PE35B
The ELC will not shut down below an ambient temperature of 62°C. However to keep the
internal ELC temperatures on a constant level, the maximum output power is decreased by
1,5kW /°C beyond the maximum operating temperature.
0
5
10
15
20
25
30
35
40
0
5
10
15
20
25
30
35
40
45
50
55
60
65
m
ax
.
lam
p
po
w
er
[k
W
]
ambient temperature [
°C]
max. operating
temperature
temperature
derating