6.10 Wrong Wiring (Error Code 5)
If the
KAPRi plus
detects wrong termintated conductors in an
installation or cable the conductor LED
(F)
for the respective con-
ductors always light in pairs. The conductor LED for the terminal
pole at the near end of the installation line lights continuously, the
conductor LED for the terminal pole at the far end is flashing.
In our example two errors are detected:
1. Wrong wiring (error code 5), conductor LED 5 lights
continuously and conductor LED 6 flashes.
2. Wrong wiring (error code 5), conductor LED 6 lights
continuously and conductor LED 5 flashes.
The error code for wrong wiring is
digit 5.
6. Operation
Note
The near end of an installation line is the terminated side that the
KAPRi plus
Mainframe is connected to.
The far end of an installation line is the terminated side the
KAPRi
plus
Test Box is connected to.