E11
6.4 Line Identification
The
KAPRi plus
Mainframe
recognizes up to nine different
KAPRi
plus
Test Boxes.
This feature allows the user to run installation tests
and line identifications at nine different lines in one operation.
Turn on the
KAPRi plus
and press the Step Key
(H).
The numeric
display shows the Test Box number as a flashing digit
(B).
If a
flashing bar appears instead, the
KAPRi plus
Mainframe did not
recognize the number of the
KAPRi plus Test Box
.
6.5 Selection of Contact Assignment
Not all installations use shielded 8 conductor cables. Therefore the
KAPRi plus
Mainframe offers the possibility to separate unused
contacts for the test. Contact assignment can be adjusted with the
Selection Switches
(C).
6. Operation
Adjust the nine Selection Switches after removing the protective
cover. Switch 1 to 8 stand for conductors 1 to 8, switch 9 stands
for the shield of the termination.
Note
Make sure that at least one conductor with an even and one with
an odd number are selected, i. e. conductor 4 and conductor 5.
Selection Switches 1 to 9
Switch set “ON”
means the
corresponding
wire has been
connected.
English