E7
First do two test runs to get familiar with the functions of the
KAPRi plus
:
1. Turn on the
KAPRi plus
Mainframe with the Start Key
(D)
. Now
a test starts automatically (it takes about 3 s). The green LED
(G)
will flash. When the test is finished the numeric display of
the
KAPRi plus
Mainframe shows as test result the digit “2”
(B)
.
Digit “2” means connection error - the
KAPRi plus
could neither
detect a connection among conductors (short circuit) nor a con-
nection to the
KAPRi plus
Test Box.
After approx. 30 s the
KAPRi plus
Mainframe
shuts off automati-
cally or you turn it off by pressing the Start Key
(D)
.
2. Now plug the attachment cord
(J)
of the
KAPRi plus
Test Box
into the RJ45 jack of the
KAPRi plus
Mainframe
(E)
and start
the test again by pressing the Start Key
(D)
. When the test is
finished the green LED
(G)
lights continuously, this means the
test was successfully finished and no errors were found. Now
press the Step Key
(H)
, the numeric display
(B)
of the
KAPRi plus
Mainframe
will show the number of the connected
KAPRi plus
Test Box
by a flashing digit (flashing digit “1” means “
KAPRi
plus
Test Box No 1” is connected).
After 30 s the
KAPRi plus
Mainframe
shuts off automatically or it
can be turned off by pressing the Start Key
(D)
.
Unplug the
KAPRi plus
Test Box attachment cord of the RJ45 jack
(E)
of the
KAPRi plus
Mainframe
and plug it in the enclosed attach-
ment cord
(A)
.
Now you can start testing your installation or cable. The following
sections will give you more detailed information about connection
and use of the
KAPRi plus
.
5. Startup Procedure
English