background image

 

 

 

Summary of Contents for BIMG FP 12 Series

Page 1: ...1...

Page 2: ...leaning and Maintenance 10 5 1 Cleaning Procedures and Products Used 10 5 2 Maintenance and Procedures in Case of Breakdowns 11 6 ANNEXES 12 Electrical Schematic 110 V or 220 V 60 Hz 12 Electrical Sch...

Page 3: ...r example use hair caps preventing them from locking in the equipment s moving parts The operator must always be aware of situations that can cause a risk of accidents and avoid them For example avoid...

Page 4: ...ray are made of stainless steel which has superior corrosion resistance than other steels It is a material resistant to the attack of several corrosive agents The blades are made of special steel unde...

Page 5: ...supply voltage of the equipment corresponds to that of the mains 3 Installation 3 1 Equipment Layout Connection to the electrical network and setup for operation must be carried out by a qualified pr...

Page 6: ...the grounding that is provided for in the electrical network it must be connected to a grounding terminals regardless of the connection to the electrical network and the other products that have acce...

Page 7: ...ly intended for slicing breads 4 2 Commands The equipment has an on off button and a guide with a bread holder The power switch is located on the rear of the equipment near the power cord The guide an...

Page 8: ...ents that will come in contact with the bread Do the cleaning with the equipment disconnected from the mains Follow the cleaning instructions in item 5 of this manual below Operation The equipment can...

Page 9: ...is hot or raw Wait until the bread is at room temperature and properly baked ATTENTION Constantly empty the tray thus preventing excess bread residues from overflowing and falling to the floor which...

Page 10: ...cleaning make sure that the on off button is in position 0 off and that the plug is disconnected from the mains ATTENTION Do not use water jet to clean the equipment IMPORTANTE This equipment is not i...

Page 11: ...life ATTENTION When servicing even minor adjustments always disconnect the equipment from the mains It is recommended to carry out preventive maintenance every 6 months checking and adjusting clearan...

Page 12: ...6 ANNEXES Electrical Schematic 110 V or 220 V 60 Hz ATTENTION For electrical installation observe the current regulations in the country especially with regard to the grounding connection if applicab...

Page 13: ...NOTE In the electric schematic above the White wires are represented by the pink color ATTENTION For electrical installation observe the current regulations in the country especially with regard to th...

Page 14: ...14 Exploded View...

Page 15: ...15 Exploded View...

Page 16: ...ouble Articulator 01 6 8 EIX042 Frame Axis 02 6 9 SBT382 Blade Frame Support 04 6 10 TRT009 Rod 04 6 11 POS004 Hexagonal Nut 16 6 12 APE001 Retaining Ring 06 6 13 PRN002 Allen Screw S C 06 7 CJT700 Ar...

Page 17: ...S015 Stainless Steel Hexagonal Nut 01 51 MNL008 Handle 01 52 PEP002 PVC Feet 04 53 POS003 Hexagonal Nut 04 54 SPT001 Plastic Shoe 04 55 TCE023 Equipotential Terminal 01 56 PRR017 Stainless Steel Round...

Page 18: ...18 Notes...

Page 19: ...19...

Page 20: ...ustry Ltda CNPJ 11 193 347 0001 14 CREA 131726 3 Road Ant nio Heil KM 23 N 5825 Neighborhood Limoeiro ZIP CODE 88352 502 Brusque SC Brazil Phone fax 55 47 3251 5555 Web Site www metvisa com br Mail sa...