background image

 

17 

 

Spare Parts 

 

Position 

Code 

Description 

Quantity 

31 

PRN002 

Allen Screw 

04 

32 

CRC906 

Pusher's Comb 

01 

33 

ACA009 

Handle 

01 

34 

PRR021 

Round Machine Screw 

02 

35 

COR006 

Belt 

01 

36 

EIX040 

Rod Shaft 

01 

37 

CJT081 

Table 

01 

38 

CHE016 

On/Off Button 

01 

39 

CRC545 

Right and Left Side Protection 

02 

40 

CRC909 

Top Coating 

01 

41 

TCE073 

Cable Gland  

01 

42 

CBE023 

Cable Type 1 - FP12220M501 

01 

CBE029 

Cable Type 2 - FP12220M502  

01 

CBE030 

Cable Type 4 - FP12110M604  
                         FP12220M604 

.

                        FP12220M504 

01 

CBE179 

Cable Type 7 - FP12220M507  

01 

43 

BDJ020 

Packer  

01 

44 

MNL014 

Handle  

02 

45 

AMP052 

Holder Guide Support 

02 

46 

GIA072 

Holder Bread Guide 

01 

47 

SBT274 

Holder Bread Guide Support 

01 

48 

CUP022 

Comb Holder Plate 

01 

49 

PRC009 

Flat Machine Screw 

04 

50 

POS015 

Stainless Steel Hexagonal Nut 

01 

51 

MNL008 

Handle  

01 

52 

PEP002 

PVC Feet 

04 

53 

POS003 

Hexagonal Nut 

04 

54 

SPT001 

Plastic Shoe 

04 

55 

TCE023 

Equipotential Terminal 

01 

56 

PRR017 

Stainless Steel Round Machine Screw 

34 

57 

PTC097 

Front Protection 

01 

58 

PRS045 

Stainless Steel Hexagonal Screw 

04 

59 

ARL008 

Stainless Steel Flat Washer 

11 

60 

POS016 

Stainless Steel Hexagonal Nut  

08 

61 

DBC004 

Stainless Steel Hinge 

02 

62 

ARL004 

Flat Washer 

01 

63 

POS021 

Stainless Steel Hexagonal Nut 

01 

64 

PRC005 

Flat Machine Screw 

01 

65 

PTA009 

Front Protection Door 

01 

66 

PTC102 

Front Protection Door Protection 

02 

67 

BDJ024 

Tray  

01 

68 

GAB229 

Rear Structure 

01 

69 

GAB126 

Frontal Structure 

01 

70 

SPD048 

Blades Stainless Steel Separator 

01 

71 

PRA007 

Stainless Steel Self-Drilling Hexagonal Screw 

03 

72 

BCH036 

Round Cap 

02 

73 

CBE033 

Black Splice Electric Cable 

01 

74 

CBE092 

Power Cable Splice 200 mm Grounding 

01 

75 

TCE013 

Female Terminal  

01 

 
 
 
 

 

Summary of Contents for BIMG FP 12 Series

Page 1: ...1...

Page 2: ...leaning and Maintenance 10 5 1 Cleaning Procedures and Products Used 10 5 2 Maintenance and Procedures in Case of Breakdowns 11 6 ANNEXES 12 Electrical Schematic 110 V or 220 V 60 Hz 12 Electrical Sch...

Page 3: ...r example use hair caps preventing them from locking in the equipment s moving parts The operator must always be aware of situations that can cause a risk of accidents and avoid them For example avoid...

Page 4: ...ray are made of stainless steel which has superior corrosion resistance than other steels It is a material resistant to the attack of several corrosive agents The blades are made of special steel unde...

Page 5: ...supply voltage of the equipment corresponds to that of the mains 3 Installation 3 1 Equipment Layout Connection to the electrical network and setup for operation must be carried out by a qualified pr...

Page 6: ...the grounding that is provided for in the electrical network it must be connected to a grounding terminals regardless of the connection to the electrical network and the other products that have acce...

Page 7: ...ly intended for slicing breads 4 2 Commands The equipment has an on off button and a guide with a bread holder The power switch is located on the rear of the equipment near the power cord The guide an...

Page 8: ...ents that will come in contact with the bread Do the cleaning with the equipment disconnected from the mains Follow the cleaning instructions in item 5 of this manual below Operation The equipment can...

Page 9: ...is hot or raw Wait until the bread is at room temperature and properly baked ATTENTION Constantly empty the tray thus preventing excess bread residues from overflowing and falling to the floor which...

Page 10: ...cleaning make sure that the on off button is in position 0 off and that the plug is disconnected from the mains ATTENTION Do not use water jet to clean the equipment IMPORTANTE This equipment is not i...

Page 11: ...life ATTENTION When servicing even minor adjustments always disconnect the equipment from the mains It is recommended to carry out preventive maintenance every 6 months checking and adjusting clearan...

Page 12: ...6 ANNEXES Electrical Schematic 110 V or 220 V 60 Hz ATTENTION For electrical installation observe the current regulations in the country especially with regard to the grounding connection if applicab...

Page 13: ...NOTE In the electric schematic above the White wires are represented by the pink color ATTENTION For electrical installation observe the current regulations in the country especially with regard to th...

Page 14: ...14 Exploded View...

Page 15: ...15 Exploded View...

Page 16: ...ouble Articulator 01 6 8 EIX042 Frame Axis 02 6 9 SBT382 Blade Frame Support 04 6 10 TRT009 Rod 04 6 11 POS004 Hexagonal Nut 16 6 12 APE001 Retaining Ring 06 6 13 PRN002 Allen Screw S C 06 7 CJT700 Ar...

Page 17: ...S015 Stainless Steel Hexagonal Nut 01 51 MNL008 Handle 01 52 PEP002 PVC Feet 04 53 POS003 Hexagonal Nut 04 54 SPT001 Plastic Shoe 04 55 TCE023 Equipotential Terminal 01 56 PRR017 Stainless Steel Round...

Page 18: ...18 Notes...

Page 19: ...19...

Page 20: ...ustry Ltda CNPJ 11 193 347 0001 14 CREA 131726 3 Road Ant nio Heil KM 23 N 5825 Neighborhood Limoeiro ZIP CODE 88352 502 Brusque SC Brazil Phone fax 55 47 3251 5555 Web Site www metvisa com br Mail sa...

Reviews: