kajaaniMCA
i – Installation, Operating & Service
- 9.10 -
W4610201 V2.5 EN
2 4 V D C
I N P U T
+
+
-
-
BI
N
1+
BI
N
1-
BI
N
2+
BI
N
2-
BI
N
3+
BI
N
3-
BI
N
4+
BI
N
4-
AI
N
1+
AI
N
2+
AI
N
2-
AL
AR
M
1
AL
AR
M
2
AL
AR
M
3
RX
D2
A
RX
D2
B
TX
D
2A
TX
D
2B
RX
D1
A
RX
D1
B
TX
D
1A
TX
D
1B
2 4 V D C
O U T
+
-
AO
U
T1
+
AO
U
T1
-
AO
U
T2
+
AO
U
T2
-
AO
U
T3
+
AO
U
T3
-
R E S E T
A B O R T
AI
N
1-
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
2 0
2 1
2 2
2 3
2 4
2 5
2 6
2 7
2 8
2 9
3 0
3 1
3 2
3 3
3 4
3 5
3 6
R S - 2 3 2
3 7
3 8
3 9
4 0
4 1
4 2
H A R T
1
2
2
1
F 7
F 6
F 5
F 4
F 8
F 3
F 1
F 2
F 9
F 1 0
F 1 1
F 1 2
F 1 3
F 1 4
F 1 5
F 1 6
i
Fig. 9.14. “Starting sampling through binary input” display.
STARTING SAMPLING THROUGH BINARY INPUT
Binary inputs line:
BIN4
Sample taking starts when bin level is:
Not in use
Bin level is now:
Low (0..2 V)
Edit
Fig. 9.15. Connecting the sampling signal to binary input 4.
Sampler
If samples for laboratory follow-up are taken from the
MCAi measurement point, information of sampling
should also be taken to the MCAi. This ensures that at
the time of sampling the MCAi will store its measure-
ment results (consistency, temperature, signal level,
chemicals compensation) in the sample history table
(see section 7.C.2). The data can then be read from the
table later on, either manually or with a PC, for various
analyses. The sampling signal is connected to the
isolated input Bin4. When a sample is being taken, the
Status line of the Main menu will read “Sampling” but
the obtained results will only be shown in the sample
history table (not in the Main menu).
Configuring the binary input
Go from M
AIN
M
ENU
=> S
ELFDIAGNOSTICS
=> S
PECIAL
FUNCTIONS
=> S
AMPLE
TAKING
:
BINARY
INPUT
(Fig. 9.14).
Press [F1&F2] E
DIT
and select the binary input level
where sampling should begin. Press [F5&F6] C
HANGE
and then select H
IGH
if you wish the sampling to connect
voltage to the binary input, or L
OW
if you wish the
sampling to connect the voltage off. Press [F3&F4]
S
AVE
.
9.F. Sampling Signal to Binary Input
Summary of Contents for kajaaniMCAi
Page 1: ...kajaaniMCAi Installation operating service manual W4610201 V2 5 EN for software version 2 5 ...
Page 59: ...kajaaniMCAi Installation Operating Service A1 W4610201 V2 5 EN App 1 Technical specifications ...
Page 61: ...kajaaniMCAi Installation Operating Service A2 W4610201 V2 5 EN App 2 Contents of delivery ...
Page 66: ...kajaaniMCAi Installation Operating Service A4 W4610201 V2 5 EN App 4 Spare parts ...
Page 68: ...kajaaniMCAi Installation Operating Service A5 W4610201 V2 5 EN App 5 Installation instruction ...