![metso automation kajaaniMCAi Installation, Operating & Service Manual Download Page 26](http://html.mh-extra.com/html/metso-automation/kajaanimcai/kajaanimcai_installation-operating-and-service-manual_1780221026.webp)
kajaaniMCA
i – Installation, Operating & Service
- 7.3 -
W4610201 V2.5 EN
F 7
F 6
F 5
F 4
F 8
F 3
F 1
F 2
F 9
F 1 0
F 1 1
F 1 2
F 1 3
F 1 4
F 1 5
F 1 6
i
Fig. 7.5. “Sample history” display.
Sample history
Sample
MCAi Lab Temp Mlev Rlev
Ccom
%
%
°C
u V %
18.10.00
10.17 3.38 3.20 69.7 59.07 1.618 0.00
17.10.00
10.23 3.20 3.20 68.7 58.50 1.636 0.00
17.10.00
09.17 3.10 3.20 67.7 58.01 1.620 0.00
Page
Enter
backwards
lab
7.C.2. Sample history
Go from M
AIN
M
ENU
=> E
NTER
LAB
=> S
AMPLE
HISTORY
(Fig. 7.5).
The taken samples are stored in the history table,
arranged according to the date of sampling. The display
shows the following data:
•
Sample: date and time of sampling.
•
MCAi %: measured process consistency.
•
Lab %: laboratory consistency used in calibration.
•
Temp °C: temperature in the process.
•
Mlev u: signal level of the measurement channel at
this consistency.
•
Rlev V: signal level of reference channel (u).
•
Ccom %: chemical compensation value.
Using the “Sample history” display, the Lab. value
of any sample can be edited also afterwards. To edit the
laboratory value, press [F5&F6] E
NTER
L
AB
.
Use keys [F3&F4] P
AGE
BACKWARDS
and [F1&F2]
P
AGE
FORWARDS
to scroll the history table back and forth.
Summary of Contents for kajaaniMCAi
Page 1: ...kajaaniMCAi Installation operating service manual W4610201 V2 5 EN for software version 2 5 ...
Page 59: ...kajaaniMCAi Installation Operating Service A1 W4610201 V2 5 EN App 1 Technical specifications ...
Page 61: ...kajaaniMCAi Installation Operating Service A2 W4610201 V2 5 EN App 2 Contents of delivery ...
Page 66: ...kajaaniMCAi Installation Operating Service A4 W4610201 V2 5 EN App 4 Spare parts ...
Page 68: ...kajaaniMCAi Installation Operating Service A5 W4610201 V2 5 EN App 5 Installation instruction ...