81
CLI Commands
event log. When the OUI is 0180C2, the following
event types are defined:
Errored Symbol Event
Errored Frame Period Event
Errored Frame Event
Errored Frame Seconds Event
Link Fault Event
Dying Gasp Event
Critical Link Event
The first four types are threshold crossing events
which are generated when a metric exceeds a given
value within a specified window. The other three
types are not threshold crossing events.
Location – Indicates whether the event occurred locally, or
was received from the OAM peer via Ethernet OAM.
Window – For a threshold crossing event, the period over
which the value was measured for the event (e.g.: 5,
when 11 occurrences happened in 5 seconds while
the threshold was 10).
Threshold– For a threshold crossing event, the limit that
was crossed for the event to be logged (e.g.: 10,
when 11 occurrences happened in 5 seconds while
the threshold was 10).
Value – For a threshold crossing event, this indicates the
number of occurrences within the given window that
generated this event (e.g.: 11, when 11 occurrences
happened in 5 seconds while the threshold was 10).
Running Total – The total number of times this occurrence
has happened since the last reset (e.g.: 987, when
987 symbol errors resulted in 18 symbol error
threshold crossing events since the last reset).
Event Total – The total number of times one or more of
these occurrences resulted in an event since the last
reset (e.g.: 18, when 987 symbol errors resulted in
18 symbol error threshold crossing events since the
last reset).
Example
:
Console> show oameventlog all
Port 1:
Port 2:
Timestamp: 0 days 0h:0 m:19.93s
OUI: 01 80 c2 Type: Link Fault Event Location: Local
Window: none Threshold: none Value: none
Running Total: 1 Event Total: 1