Radiance 10/100 Mbps Services Line Card
122
Error: Valid window
values are between
125000000 and
3205032704.
An unacceptable value was entered for the window parameter when
setting the OAM Errored Symbol Period Event. The acceptable range is
125000000 to 3205032704.
Error: VLAN #
already assigned to
PVID or
Management VLAN.
The specified value for the user VLAN is invalid because it has already
been assigned as either a PVID or a management VLAN. The user
VLANs must be unique.
Error: VLAN ID not
found.
The specified VLAN ID for the command is invalid. Make sure it is typed
correctly. If available, use the ‘all’ option. For example, enter ‘show
uservlan all’ to see all configured user VLANs.
Error: You must
download a valid
config file.
To run a configuration file, you must first download a valid file into one of
the two image locations.
Error: You must
include an IP
address.
To execute the ‘ping’ command, an IP address must be specified.
Invalid retransmit
count entered, valid
range (1-10).
The value entered for the maximum number of transmission retries to a
RADIUS server is out of range. The number must be in the range 1-10.
Invalid timeout value
entered, valid range
(1-10).
The value entered for the RADIUS timeout is out of range. The time must
be in the range 1-10.
Login failed.
The login username or password is incorrect. Make sure the [C
APS
L
OCK
]
key is not pressed.
Maximum config file
size exceeded.
The configuration file you attempted to download was more than 8K,
which is the maximum size supported by the R821.
Maximum number of
server entries
exceeded.
Up to five (5) RADIUS servers can be configured for the device. To add
another RADIUS server, you must first delete an existing server using
the ‘clear radiusserver’ command.
QinQ must be
disabled for 802.1Q
operation.
To change the forwarding mode from transparent to 802.1Q, you must
first disable Q-in-Q operation.