12
Figure 4: Metro Pellet Fire
Insert Surround
USE NUTS
AND BOLTS TO
SECURE HERE
INSERT MX
CONTROL
PANEL HERE
(SECURE WITH
BLACK RIVETS
PROVIDED)
INSTALLING THE METRO PELLET FIRE INTO A TIMBER CAVITY
If the pellet fire is being installed into a timber cavity installation,
1. Prepare the cavity opening to the minimum dimensions shown in figure 2 and line with non-combustible
material such as villa board.
2. The 100mm vent pipe must be fully cased with 150mm galvanised casings from the top of the
telescopic offset to the top of the vent pipe exiting the roof. (as shown in figure 3)
• These casings must be supported in position, either attached to the vent pipe, or to the inside of the cavity.
• This installation into a timber framed cavity will require a “Metro Pellet fire Insert vent system”,
plus additional lengths of 150mm diameter galvanised casings with centralising brackets.
3. If heat sensitive material (i.e wooden floor)is located below the pellet fire an insulated floor protector must
be installed. This floor protector must extend 150mm forward of the ashlip.
Figure 3
Figure 2
575MM
850
MM
720
MM
130MM MINIMu
M
IMPORTANT MESSAGE
•
ALL EXPOSED 100MM VENT PIPE INSIDE THE
CAVITY MUST BE A MINIMUM OF 130MM FROM ANY
COMBUSTIBLE MATERIAL.
•
THE INSTALLATION OF THIS VENT SYSTEM AND
APPLIANCE IS TESTED AND APPROVED FOR THE
METRO BAY INSERT PELLET FIRE ONLY.
WARNING
WARNING
Fascia Surround
The METRO pellet insert surround can be seen in Figure 4.
The surround comes in 3 separate pieces and needs to be
assembled before being attached to the pellet fire. Layout the
top and sides of the surround on the floor as shown in Figure
4. Verify that each side piece mounting holes are aligned
with the top piece mounting holes. Using the supplied nuts
& bolts, secure the side pieces to the top. Mount the MX3™
Control board as shown. Your surround is now ready to
mount to the insert.