MD 9260 Clamp Meter
Sicherheit
9
Note
When using Diode test function, normal forward voltage drop (forward biased) for a good
silicon diode is between 0.400V to 0.900V. A reading higher than that indicates a leaky diode
(defective). A zero reading indicates a shorted diode (defective). An OL indicates an open diode
(defective). Reverse the test leads connections (reverse biased) across the diode. The digital
display shows OL if the diode is good. Any other readings indicate the diode is resistive or
shorted (defective).
CAUTION
1. Using Resistance, Continuity, Diode or Capacitance function in a live circuit will produce false
results and may damage the meter. In many cases the suspected component(s) must be
disconnected from the circuit to obtain an accurate measurement reading.
2. When using Capacitance function, discharge capacitor(s) before making any measurements.
Large value capacitors should be discharged through an appropriate resistance load