24.10.2007
Rev. 1.1
Installation
20
5.8.3
Connecting the cable for Y-type electrical connection to the appliance terminal
block (ceramic glass top and sides).
Only the manufacturer's service centre or similarly trained individual may replace the
power cable.
To access the power terminal block, proceed as follows:
•
Disconnect the power supply.
•
Remove the knobs (pos. 2 Fig. 7).
•
Loosen the fixing screws to remove the control panel (pos. 1 Fig. 7).
Fig. 7
1.
Fixing screws
2.
Knobs
Fig. 7a
1.
Terminal block
2.
Cable clamp
The terminal block is mounted on the lower compartment as shown in Fig.7a.
The power cable must be secured with the cable clamp fitted to the appliance (pos.2 in
Fig. 7a) to prevent it from being damaged.
The earth cable must be long enough to withstand any potential mechanical strain after
the live wires.