METIEC MT1100 Operation And Installation Manual Download Page 8

 

 
 

 

A1-MT1100 

c)

 

Upgrade Debugging Port: 

Micro USB interface; it has 2 functions: Firstly, it can be used for program upgrade: The special USB 

cable  customized  by  the  company  is  used  for  upgrading  program;  secondly,  it  is  used  to  modify 

parameters:  The  special  USB  cable  customized  by  the  company  shall  be  used  for  modifying 

parameters; it needs to work with the modification software of " Huchuang Union Wireless Slaver 

Debugging Platform.exe". 

d)

 

Reset Button (Pin-socket type). 

Press  this button  to forcibly  restart  the equipment  (the factory  setting  shall not be reset) when the 

equipment breaks down. 

e)

 

Power toggle switch: 

The device can be powered ON normally only when the toggle switch is turned to ON position. 

f)

 

Charging port: 

Connected with a 5V/2A power adapter. 

g)

 

Ethernet port: 

The device can be directly connected with MT500 through the crossover network cable; if the device 

is connected with multiple MT500 devices, then it must be connected with a switch. 

h)

 

SIM card holder:   

Applicable for standard SIM cards of China Mobile, China Unicom and China Telecom. 

i)

 

4G antenna interface: 

Connected with external antenna of 4G Total Communication. 

j)

 

433MHz antenna interface: 

Connected with 433 MHz external antenna. 

Summary of Contents for MT1100

Page 1: ...HCLH SOP YF 072 115 Data Transceiver and Power Monitoring Series MT1100 Operation and Installation Manual...

Page 2: ...roduction Address No 1 Workshop 1F Building B10 Wuhan Hi Tech Medical Device Park No 818 Gaoxin Avenue East Lake Hi Tech Development Zone Wuhan Hubei China After Sales Service Unit Wuhan Huchuang Unio...

Page 3: ...1 Structure Features 5 2 2 Equipment Parameters 8 3 Basic Operation Instructions 9 3 1 Installation Method 9 3 1 1 Laid Flat 9 3 1 2 Wall Mounting 9 3 2 Power On for Use 10 3 3 Main Interface Instruct...

Page 4: ...the copyright holder 1 1 4 The contents of the Manual are subject to change without prior notice 1 2 Overview As a data transmitter and transmitter host monitored by the laboratory MT1100 can receive...

Page 5: ...after being cleaned and sterilized 1 4 2 During recycling and handling MT1100 device it is recommended that the company s technical personnel dismantle it and recycle it according to different waste...

Page 6: ...nd Equipment Parameters 2 1 Structure Features a Data Display Screen Displays the current states and the current received data of the device b Keys Push type buttons set or modify the equipment parame...

Page 7: ...A1 MT1100 6 c d e f g i j k h l...

Page 8: ...art the equipment the factory setting shall not be reset when the equipment breaks down e Power toggle switch The device can be powered ON normally only when the toggle switch is turned to ON position...

Page 9: ...eal time Adapter power failure detection Uploads the power failure status at once Local alarm mode Audible and visual alarm Display screen 2 42 inches OLED Battery endurance 8 hours the power supply i...

Page 10: ...shown in the following figure Note Try to keep the antenna away from metal objects otherwise the transmission of wireless signals will be affected 3 1 2 Wall Mounting Select a relatively open smooth...

Page 11: ...onnected with MT500 the IP address of the device shall be set in advance and then it shall be connected with MT500 through a crossover network cable 3 3 Main Interface Instructions Key 1 UP key Key 2...

Page 12: ...that the device is connected to the WIFI successfully err means that the device is connected to the local server abnormally Number of TCP clients successfully connected number of MT500 devices 8 at m...

Page 13: ...f Buttons Key 1 The system returns to the main interface when the key is pressed Key 2 The system returns to the main interface when the key is pressed Key 3 The system returns to the main interface w...

Page 14: ...to add the current set value by 1 Key 2 key Press this button to reduce the current set value by 1 Key 3 key When you press the button the cursor will move to the next set value Key 4 OK key When you...

Page 15: ...y Press this button to reduce the current set value by 1 the key can be pressed and held Key 3 key When you press the button the cursor will move to the next set value Key 4 OK key When you press the...

Page 16: ...nd letters 14 bits at most insufficient ones replaced by Operation Instructions of Buttons Key 1 key Press this button to add the set value Key 2 key Press this button to reduce the set value Key 3 ke...

Page 17: ...arameters but directly returns to the setting interface 4 Precautions The local wireless transmission distance of MT1100 is limited and should generally not exceed 3 rooms If the walls of the rooms ar...

Page 18: ...provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordan...

Page 19: ...uirements use accessories that maintain a 10mm separation distance between the user s body and the back of the handset The use of belt clips holsters and similar accessories should not contain metalli...

Page 20: ...A1 MT1100 19 Wuhan Huchuang United Technology Co Ltd Address No 1 Workshop 1F Building B10 Wuhan Hi Tech Medical Device Park No 818 Gaoxin Avenue East Lake Hi Tech Development Zone Wuhan Hubei China...

Reviews: